RD75D4 MITSUBISHI RD75D4
Brand: MITSUBISHI
Name: Positioning module
Model: RD75D4
"Differential driver output.
Axis of control: 4.
Control unit: mm, inch, degree, pulse.
Location data: 600 data / axis.
Module backup function: the positioning data, module start data saved to the flash ROM (no battery).
Boot time (operation cycle 0.444ms, 1 axes): 0.3ms.
Maximum output pulse: 5000000 pulse/s.
The maximum distance between servo system: 10m.
External wiring connection: 40 pin connector two.
Linear interpolation: 2 axes.
Arc interpolation: 2 axes.
Spiral line interpolation
For large hole drilling, X, Y, Z axis should be considered.
Need to be through the milling process, along the XY axis of the circular arc shaped drill open the required specifications of the hole.
And the deviation of the cutting position is controlled at the minimum, and the shaft is carefully processed along the Z axis.
Without special NC control system for such control, X, Y, Z axis between the interpolation control is easy to produce error,
High precision positioning control.
The use of the positioning module of the spiral line interpolation function, that is, to achieve low cost control of high difficulty.
Easy positioning control
The positioning module uses the position control and speed control, which is set by the engineering software.
In the position control and speed control is also equipped with an increase in the "conditional judgment" after the implementation of the specified positioning data and other advanced positioning control functions.
For example, in the automobile door sealing process, the need to carry out high precision positioning control,
In order to applying sealant on the sealing part of the door.
Therefore, it is necessary to track the precise trajectory through the straight line and the arc, and implement the high precision interpolation control.
Multiple start mode
In addition to the conventional positioning module startup, there are high-speed start, multi axis at the same time, such as the start of a variety of ways to start.
High speed start by analyzing the location data to be executed in advance,
High speed startup mode without data analysis time.
Multi axis simultaneous start up mode for starting output pulse at the same time that the object shaft is started simultaneously with the start of the shaft.
In addition, the module can be started to run according to a plurality of positioning data groups in turn at startup.
Can be used for repetitive control of the same locus. "

Analog input channel number: 8CH.
accuracy
Ambient temperature of 25 plus or minus 5 degrees C: plus or minus 0.1%.
Ambient temperature 0 ~ 55 degrees C: plus or minus 0.3%.
Temperature coefficient.
Common
Conversion speed: 80 s/CH.
Channel to channel insulation.
Absolute maximum input: 30mA.
External wiring connection mode: 18 point screw terminal MITSUBISHI RD75D4.
Voltage input
Analog input voltage: - RD75D4
Digital output value: -.
Current input
Analog input current: DC0 ~ 20mA.
Digital output value: 0 ~ 32000.
16 bit high resolution (1/32000).
No program can perform scaling and conversion operations.
The most suitable for the requirements of speed and accuracy of the detection equipment.
Easy to filter high frequency interference MITSUBISHI RD75D4.
Execute event driven programs via alarm output.
Through the engineering software, the output of arbitrary analog waveform data.
Reduce downtime and reduce maintenance costs through anomaly detection
Works3 GX can be used to easily set the critical value of the input and output signals.
Can quickly detect the abnormal signal, so it can shorten the downtime, reduce maintenance costs MITSUBISHI RD75D4.
Channel insulation can ensure the accurate signal transceiver.
Model with " -G " module in the channel between the insulation,
Isolation amplifiers are not required to prevent inter channel current and interference current. Output points: 16 points.
Output form: relay output.
Rated open and close voltage, current: DC24V/2A, AC240V/2A.
Rated load voltage.
Max load current: -.
Response time: 12ms.
Common way: 16 point / public end.
Protection function (overload, overheat).
External wiring connection mode: 18 point screw terminal.
Output module with mechanical relay contact mechanism,
Including the load voltage range of the relay and can be used for the output of the DC12~24V load transiistor output type RD75D4.
According to the load voltage, the output points of different, choose the most suitable user needs of the module.
Preventive maintenance based on the life of relay contact.
Relay output module can accumulate the number of OON of each output point RD75D4.
Through the understanding of the relay contacts of the number of times, according to the relay life of preventive maintenance.