LK Automation Limited LK Automation Limited
Brand: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Go Back >> Product Catalogues
OMRON CJ1W-OC Series/CJ1W-OA Series/CJ1W-OD Series Output Units
Brand: OMRON
Name: Output Units
Model: CJ1W-OC Series/CJ1W-OA Series/CJ1W-OD Series
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications.
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system.
throughput.

Unit type: CJ1 Basic I/O Units.
Product name: Transistor Output Units.
Specifications: Output type, Sourcing;
I/O points, 64 outputs;
Maximum switching capacity, 12 to 24VDC, 0.3A;
Commons, 16 points, 1 common;
External connection, MIL connector.
No. of words allocated: 4 words.
Current consumption: 5V, 0 OMRON CJ1W-OC Series/CJ1W-OA Series/CJ1W-OD Series. 17A; 24V, --.
Standards: UC1, N, L, CE CJ1W-OC Series/CJ1W-OA Series/CJ1W-OD Series
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications.
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system.
throughput.
Product name: CJ1M CPU Units; built-in I/O OMRON CJ1W-OC Series/CJ1W-OA Series/CJ1W-OD Series.
Specifications: I/O capacity/Mountable Units Expansion Racks),
160 points/10 Units (No Expansion Rack); Program capacity,
5K steps; Data memory capacity, 32K words(DM: 32K words, EM: None);
LD nstruction execution time, 0.1 μs;
Built-in I/O , 10 inputs and6 outputs,
2 counter inputs, 2 pulse outputs.
Current consumption: 5v, 0.64A (Seenote 1.) ; 24V,-- OMRON CJ1W-OC Series/CJ1W-OA Series/CJ1W-OD Series.
Standards: UC1, N, L, CE.
Versatile Machine Control with the,
Highest Performance Standards in the Industry. Unit classification: CJ1 Special I/O Units.
Product name: Isolated type DC Input Units.
Input points: 2 inputs.
Signal range selection: DC voltage:
0 to 1.25 V, -1.25 to 1.25 V, 0 to 5 V,
1 to 5 V, -5 to 5 V, 0 to 10 V, -10 to 10 V,
±10 V selectable range DC current:
0 to 20 mA, 4 to 20 mA.
Conversion speed (resolution): Conversion,
speed: 10 ms/2 inputs, Resolution: 1/64,000.
Accuracy at ambient temperature of 25°C:
Accuracy: (±0.05% of F.S.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.118A; 24V, 0 CJ1W-OC Series/CJ1W-OA Series/CJ1W-OD Series. 09A.
Standards: UC1, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four inpuut channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage) CJ1W-OC Series/CJ1W-OA Series/CJ1W-OD Series.
All inputs are isolated.


...More relevant models >>>>