CJ1W-OC201 | OMRON Output Units CJ1W-OC201
Brand: OMRON
Name: Output Units
Model: CJ1W-OC201
Unit type: CJ1 Basic I/O Units.
Product name: Relay Contact Output Units.
Specifications: Output type , --;
I/O points, 8 inputs;
Maximum switching capacity, 250VAC/24VDC, 2A;
Commons, Independent contacts;
External connection, Removable terminal block.
No. of words allocated: 1 word.
Current consumption: 5V, 0.09A; 24V, 0.048A max.
Standards: UC1, N, L, CE.
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications.
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system.
throughput.

Unit classification: CJ1 Special I/O Units.
Product name: Process Input Units,
(Isolated type Units with Universal Inputs).
Input points: 4 inputs.
Signal range selection:
Set separately for each input.
Signal range:Fully universal
inputs: Pt100, JPt100, Pt1000, K,
J, T, L, R, S, B, 4 to 20 mA, 0 to 20 mA,
1 to 5 V, 0 to 5 V, 0 to 10 V OMRON CJ1W-OC201.
Conversion speed (resolution): Conversion,
speed: 250 ms/4 inputs CJ1W-OC201
Accuracy at ambient temperature of 25°C:
Accuracy: Platinum resistance thermometer,
input: ±0.3% of PV or ±0.8°C, whichever,
is larger) ±1 digit max. Thermocouple input:
(±0.3% of PV or ±1.5°C, whichever is larger),
±1 digit max. *1 Voltage or current input:
±0.3% of F OMRON CJ1W-OC201. S. ±1 digit max.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.32A; 24V, --.
Standards: UC1, L, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four input channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage) OMRON CJ1W-OC201.
All inputs are isolated. Unit type: CJ1 Basic I/O Units.
Product name: Transistor Output Units.
Specifications: Output type, Sinking;
I/O points, 64 outputs;
Maximum switching capacity, 24VDC, 0 CJ1W-OC201 OMRON. 3A;
Commons, 16 points, 1 common;
External connection, Fujitsu connector.
No. of words allocated: 4 words.
Current consumption: 5V, 0 CJ1W-OC201 OMRON. 17A; 24V, --.
Standards: UC1, N, L, CE.
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications.
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system CJ1W-OC201 OMRON.
throughput. Unit type: CJ1 Basic I/O Units.
Product name: Triac Output Unit.
Specifications: Output type , --;
I/O points, 8 inputs;
Maximum switching capacity, 250VAC, 0.6A;
Commons, 8 points, 1 common;
External connection, Removable terminal block.
No. of words allocated: 1 word.
Current connsumption: 5V, 0 CJ1W-OC201. 22A; 24V, --.
Standards: UC1, N, L, CE.
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications.
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices OMRON CJ1W-OC201.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system.
throughput.


...More relevant models >>>>