MM-EFS71M MITSUBISHI MM-EFS71M
Brand: MITSUBISHI
Name: IPM motor
Model: MM-EFS71M
Superior high efficiency IPM motor.
Output power: 0.75kw.
Rated speed: 1500r/min.
Voltage level: 200V.
IPM motor MM-EFS series can not be used to run the power frequency power.
The total wiring length of the IPM motor shall not exceed 100m.
1 inverters can not connect multiple IPM motors at the same time.

MITSUBISHI inverter series: FR-A820.
Voltage level: three phase 200V.
Power: 2.2kw.
SLD converter rated current: 16.7A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Parameters can be selected by 4 different rated current and different overload rating (SLD (ultra light load) rated, LD (light load) rating, ND (general load) rating, HD (weight) MITSUBISHI MM-EFS71M.
Type load) for selection MM-EFS71M
You can choose the most suitable frequency converter for use; and by selecting a transducer with a SLD or LD rated level,
Be able to reduce the size of the device (compared with the FR-A700 series, to reduce the volume of equipment).
For applications that require high torque at low speeds, the HD rating is the most suitable MITSUBISHI MM-EFS71M.
The controller is used to control and monitor the frequency converter through the network.
Standard corresponding RS-485 communication (MITSUBISHI converter protocol, Modbus-RTU protocol) data transmission speed up to 115200bps. MITSUBISHI inverter series: FR-F840.
Voltage level: three phase 400V.
Power: 45kw.
SLD converter rated current: 93A.
Structure and function: Standard model MITSUBISHI MM-EFS71M.
Type: CA.
Substrate coating: have.
The motor efficiency is not changed in the previous optimal excitation control,
At the same time, the newly developed advanced optimal excitation control can obtain larger torque at startup.
No need to adjust the parameters (plus deceleration time or torque, etc.), in a short time to speed up to a certain speed,
Can be carried out to maximize the efficiency of energy-saving drive motor.
The automatic tuning function of the loop constant of the motor is not consistent with the constant of the motor, the motor of other manufacturers, and the length of wiring is too long,
Optimum operating characteeristic drive motor MM-EFS71M.
In the state of the sensor can not only drive the high efficiency and energy saving motor and PM motor (MM-EFS), but also can drive other companies induction motor and PM motor (permanent magnet synchronous motor).
Othher manufacturers of induction motors, can also be automatically tuned to achieve the best excitation control, thus expanding the use of energy saving MM-EFS71M.