FX5-4AD-ADP MITSUBISHI Extension adapter
Brand: MITSUBISHI
Name: Extension adapter
Model: FX5-4AD-ADP
Function: 4CH voltage input / current input.
Adapter for connecting the left extension function of the CPU module.
CPU module can be connected to the left side up to 6 units.

RS-232 communication. Special communication adapter.Input output cable for A6TBXY36 type connector / terminal row conversion module.
Length 3M. Total input and output points: 48 points.
Input points: 24 points.
Output points: 24 points.
Output type: transistor output.
Power supply voltage: DC24V.
Input signal voltage: DC24V FX5-4AD-ADP MITSUBISHI.
FX2N series expansion unit
Expansion unit is an input and output expansion device with a built-in power supply FX5-4AD-ADP
As with the basic unit, the extension unit can be connected to a variety of input and output and special extension equipment.
Can connect to FX3GA/FX3G, FX3GE and FX3U.
AC power model, the built-in maximum DC24V 250mA/460mA supply power.
Because all models of FX series are built in high speed counter,
So the high speed control can be realized by the simple procedure FX5-4AD-ADP MITSUBISHI.
The input of the basic unit is built in the anti jitter filter,
One part as digital filter,
Sensitivity adjustment unit can reach 1ms.
Using high speed counter automatically adjusted to the minimum value.
Through the high cost of the built-in positioning function and the expansion function to increase the number of control axis FX5-4AD-ADP MITSUBISHI.
Extended function expansion board and special adapter,
Data links and communication with external serial devices. Maximum file size: 512MB.
Data form: CSV form.
Weight: 0.3kg.
PLC data can be saved in the form of CF to CSV.
1, can save up to 254, 32767 row of data.
2, save the CSV file can be read through the table count software, and in the form of graphics display, ease of analysis.
PLC can be read through the collected data.
Long time to collect data, through the file FIFO function,
You can automatically generate new files and automatically overwrite the old files, to achieeve the continuous collection of data FX5-4AD-ADP.
Record the historical data before and after the alarm,
In a file to collect data buffer storage file will play a.
FX3U, FX3UC version 2.61 or more can be used, the need to connect the FX3U when the expansion board FX5-4AD-ADP.
The communication function expansion board and the communication special adapter are the same, the communication occupies 1 channels.