LK Automation Limited LK Automation Limited
Brand: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Go Back >> Product Catalogues
EJ1N-HFUB-NFL2 OMRON EJ1N-HFUB-NFL2
Brand: OMRON
Name: Modular Temperature Controller
Model: EJ1N-HFUB-NFL2
Name: HFU with Programless Communications *1.
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: None.
Control outputs 1 and 2: None.
Control outputs 3 and 4: None.
Auxiliary output: Transistor output: 4 points (sinking).
Functions: burnout Heater alarm, None; Event inputs, 4.
Communications functions: Port C: RS-422,
From End Unit: Port A: RS-485.
Input type: No input.
Terminal: Screw-less clamp.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements.
Connect directly to the G3ZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calculate the PID constants with the step,
response method.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit.

Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1.6 dia.
Protective tubing length L: 20cm.
Lead wire type: Standard.
Lead wire length M : 1m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work OMRON EJ1N-HFUB-NFL2.
Ideal for the thermal input devices of Temperature Controllers EJ1N-HFUB-NFL2
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1 dia.
Protective tubing length L: 15 cm OMRON EJ1N-HFUB-NFL2.
Lead wire type: Heat resistive.
Lead wire length M : 8m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal OMRON EJ1N-HFUB-NFL2. Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: position ratio control.
Auxiliary output points: 2 points.
Event entry point: 4.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to cheeck the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV EJ1N-HFUB-NFL2.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output EJ1N-HFUB-NFL2.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.


...More relevant models >>>>