OMRON EJ1N-HFUB-DRT OPERATION MANUAL PDF
Product model: EJ1N-HFUB-DRT
Name: Temperature Controller
Brand: OMRON
Sort: OPERATION MANUAL
File language: English
Size: 48 x 96mm.
Ontology: terminal type, analog input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: voltage output (SSR driver) EJ1N-HFUB-DRT PDF.
Control output 2: high life relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use EJ1N-HFUB-DRT
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance tthe performance EJ1N-HFUB-DRT PDF EJ1N-HFUB-DRT Manual.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay EJ1N-HFUB-DRT PDF.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation OMRON OPERATION MANUAL. Size: 1/16 DIN.
Case color: Black.
Power supply voltage: 24 VAC/VDC.
Input type: Thermocouple or resistance thermometer.
Auxiliary outputs: None.
Control output 1: Voltage output (for driving SSR).
New 48 x 48-mm Basic Temperature.
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function OMRON OPERATION MANUAL.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
New E5CN-U Modelss (Plug-in Models) with analog inputs and,
current outputs OMRON OPERATION MANUAL EJ1N-HFUB-DRT OPERATION MANUAL.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
mannual, RUN/STOP, and alarms) and the PV or SV EJ1N-HFUB-DRT Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Related products
OMRON
Modular Temperature Controller
EJ1N-HFUA-NFL2
OMRON Modular Temperature Controller EJ1N-HFUA-NFL2
Name: HFU with Programless Communication
OMRON
Modular Temperature Controller
EJ1N-HFUB-NFL2
OMRON Modular Temperature Controller EJ1N-HFUB-NFL2
Name: HFU with Programless Communication
OMRON
Modular Temperature Controller
EJ1N-HFUB-DRT
OMRON Modular Temperature Controller EJ1N-HFUB-DRT
Name: HFU with DeviceNet Communications
OMRON
Modular Temperature Controller
EJ1N-HFUB-NFLK
OMRON Modular Temperature Controller EJ1N-HFUB-NFLK
Name: HFU with Programless Communication