Number of beams: 40.
Protective height: 605mm.
Model: NPN output.
Basic Type with a combination of.
performance and functionality.
Up to three sets of series-connected sensors.
The muting function is enabled simply with Muting Key Cap.
Comes standard with interlock and auxiliary output functions . Operation system: Time-limit operation, integrating operation E6A2-CWZ5C 100P/R 0.5M.
Resetting system: Power-OFF resetting (excluding -M), external resetting,
manual resetting, automatic resetting
E6A2-CWZ5C 100P/R 0.5M
No. of digits: 4 digits (switch-selectable):
0.01 to 99.99 s, 0.1 to 999.9 s, 1 to 9999 s, 0.1
to 999.9 min, 0.1 to 999.9 hrs, 1 to 9999 hrs,
1 s to 99 min 59 s, 1 min to 99 hrs 59 min E6A2-CWZ5C 100P/R 0.5M.
Backup power supply function for memory protection: Can be,
enabled and disabled with a DIP switch .
DIN-sized (72 x 72 mm) Quartz Timer with,
Multiple Functions.
Wide time range from 1/100 seconds to 9999 hrs.
Built-in power supply incorporated in timer enables direct,
connection of sensors and other components.
Draw-out construction allows maintenance without,
disconnecting the wiring E6A2-CWZ5C 100P/R 0.5M.
Power supply freely selectable within a range of 100 to 240 VAC;
a DC-operated version is also available .
Control outputs of both contact type and transistor type,
simultaneously available.
Seven operating modes (N, F, C, R, K, P, and Q) are available. Name: CS1D Duplex Unit.
Specifications: Applicable systems,
Duplex CPU, Single I/O Expansion System only;
Basic functions, Duplex CPU Unit processing,
error monitoring, and CPU Unit switching,
when error occurs;
Online Replacement, Not supported.
Current consumption: 5V system, 0.55A;
26V system, --.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables. The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenaance function is increased,
Further performance improvement E6A2-CWZ5C 100P/R 0.5M.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivee ddisplay PV/SV E6A2-CWZ5C 100P/R 0.5M.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
E6A2-CWZ5C 100P/R 0.5M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E6A2-CWZ5C 100P/R 0.5M&select=5