Input voltage: AC100~240V.
Screen size: 12.1 inches.
Display type (resolution):65536 color TFT display LCD (SVGA 800 x 600 pixels).
Touch panel type: analog resistance.
Memory: 32MB (internal memory), SRAM320KB (backup memory), SRAM64KB (variable area).
Ethernet interface: 1.
Serial port: RS-232C * 1, RS-422/485 * 1 .
SD card slot (max 32GB):1 GP2000H-DF10.
USB interface: Type-A x (2) USB 1, Mini-B USB (2) x 1
GP2000H-DF10
Replaceable battery: yes.
Alarm analysis function block: yes.
Panel opening size:
Wide 301.5 x high 227.5mm (+1/0mm).
Panel thickness: 1.6-5mm, chamfer radius is less than R3.
Enhance the display effect.
All models are using 65535 color LCD TFT, and has the high brightness control function of the backlight GP2000H-DF10.
Exquisite picture not only improves the quality of monitoring, but also increases the safety of operation.
Mobile terminal remote monitoring.
With light and portable iPhone, iPad, touch iPod and other mobile terminal remote monitoring of large or long distance applications, large-scale processing system or production site of a number of machines GP2000H-DF10. Display size: 5.7 inches.
Display type: monochrome LCD .
Display color: blue and white.
Resolution: 320 x 240 pixels.
Input voltage: DC24V.
Control memory: EPROM 1MB FLASH.
Program area: 128KB.
Variable area: 32KB.
Interface: built-in DIO 32 points (16 point input /16 point output, PNP type). Used to connect the GP2000H series RS-422 conversion adapter with GP3000H, with D-Sub connectors.
Length: 3 meters. Apply to GLC-2600/2500When the man-machine interface is installed to the fixed panel to provide dust proof and moisture proof function. (1)Specifications: DC24/S (standard) class models.
Display type: TFT color LCD.
Display size: 3.8 inches.
Resolution: 320 x 240 pixels (QVGA).
Display color: 256 color (no flash) /64 color (3 speed flicker).
Backlight: white LED (back light lamp replacement: return to repair).
Brightness adjustment: 16 level adjustment can be carried out by touch panel.
Touch panel type: resistance type (analog).
Rich sample images can reduce programming time.
Pro-face provides a large number of sample images and 3D parts,
So you can easily create a beautiful and intuitive picture, in order to save editing time. Data transmission using USB memory.
In the production site using USB memory can be easily transferred to the production line change and change the screen data.
Can improve the efficiency of the 5 functions.
Using EX GP-Pro can easily create a clear picture and save the creation time.
Screen and logic programming software EX GP-Pro interface is very friendly,
The drag and drop feature makes the software interface easy to operate.
EX GP-Pro powerful features, such as 3D simulation components, image fonts and simulation functions,
Even beginners can easily and quickly grasp how to create a picture.
Providing operation and maintenance instructions through video mode, which can save maintenance cost.
The operation and maintenance instructions provided by the video mode can make any operator easy to master the operation method.
Simulated running status on PC.
Use PC simulation function, do not need to transfer the picture to GP,
You can check all the functions of GP on the PC - including the screen operation, D script, logical script.
Remote operation and monitoring in the Office
In the office or other remote side can monitor the production site of the GP screen.
Without picture editing or programming, you can achieve real-time management and monitoring, and now, you can also provide more efficient remote maintenance control.
Error visualization.
The controller is directly connected to the GP, and the key error information of the controller can be displayed on the GP by using the sample unit.
Easily upgrade.
Safety control function can minimize the problem of production site
Password management functions can be based on each operator or administrator password to enter the set level can be operated by the screen,
According to the function of the operator to set the password to enter the level.
In order to strengthen the management, the operator must enter the ID and the password to operate the equipment.
No need to open the control panel, through the PLC to monitor the GP program.
Through the data through the GP function, you can easily debug the ladder program and adjust the data due to changes in the production line by GP easily.
Use USB memory or CF card backup monthly andd daily
Recording functiion using USB memory or CF card can easily improve the efficiency of daily and monthly GP2000H-DF10.
The use of CSV data conversion function can be modified on the PLC GP settings.
GP/ST series supports GP series of all models of the screen data, including the fiirst generation of the GP10 series GP2000H-DF10.
GP product family to maintain the size of the opening of the panel compatibility, to facilitate easy replacement.
GP2000H-DF10 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=GP2000H-DF10&select=5