CS1H-CPU67H Program capacity: 250K steps OMRON CS1H-CPU67H


Name: CS1D CPU Unit for Single CPU Systems.
Specifications: Number of I/O points,
1280 points (3 Racks);
Program capacity, 30 Ksteps;
Data Memory, 64 Kwords(DM: 32 Kwords,
EM: 32 Kwords×1 bank);
LD execution time, 0.04 μs;
Duplex CPUs, --;
Interrupt functions, OK CS1H-CPU67H.
Current consumption: 5V system, 0.78A;
26V system, --.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables CS1H-CPU67H. Name: Clamp Terminal Blocks.
Specifications: Outputs; 16 outputs ; NPN; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system CS1H-CPU67H.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error OMRON CS1H-CPU67H.
I/O bits: 5, 120 (Expan-sion Racks: 7).
Program capacity: 250K steps.
Data memory capacity: 448K words (DM: 32K words, EM: 32K words ×13 banks).C500-DA/3G2A5-DA Special I/O Unit Analog Output C500-DA005(3G2A5-DA005) OMRON CS1H-CPU67H.
Output: 2 pts.
Specification: -5~+5V.Name: Three-tier Screw Terminal Block.
Specifications: Inputs; 8 inputs; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet OMRON CS1H-CPU67H.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. C200H-CPU21-E CPUs
High Spec, Small Rack Style
The C200H-CPU21-E and C200H-CPU23-E controllers offer increased I/O capacity and the same basic funnctionality as the OEM versions CS1H-CPU67H. In addition,
these controllers offer an extended instruction set,
expansion. A variety of CPUs are available with various memory and I/O configurations allowing selection based on application requirements.