Product model: 3G3MX2-AB001
Name: Time lnterval Meter
Brand: OMRON
Sort: INSTRUCTION SHEET
File language: English
Inverter input power: 3 phase / single phase AC200V.
Weight: 2.6KG.
Standard applicable line diameter: 3.5 square mm or more.
Used to suppress harmonic currents generated by a transducer 3G3MX2-AB001 PDF.
The effect of harmonic current suppression is better than that of AC reactor,
And it can be used with AC reactor. Specification: single phase 200V
Power: 0.2KW.
Maximum output voltage: three phase input voltage 3G3MX2-AB001
Rated voltage, frequency: single phase power supply 200 ~ 50/60Hz, 240V.
Cooling way: natural wind cooling.
Weight: 1.1kg.
Open loop vector control mode of low speed and high torque, rich control function and convenient distribution management network function,
Set in one of the inverter --3G3MZ 3G3MX2-AB001 PDF.
3G3MZ series inverter for the application of frequency control and development.
Humanized design and advanced management technology, as well ass OMRON a simple style of modeling, feature rich style,
Combined with the latest technical needs of users, so that it has a noble lineage and the most close to the market elements 3G3MX2-AB001 PDF 3G3MX2-AB001 Manual.
Covers the special features of the fan pump class, open loop vector function,
Built in noise filter and a variety of network bus,
3G3MZ will be your most economical and the most perfect choice OMRON INSTRUCTION SHEET. Function name: 3 phase 200V.
Power: 3.7KW.
Rated output voltage: 3 phase, 200 ~ 240V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched).
Weight: 2.0KG.
Dimension (w * h) 128mm *:140.
Outline dimension (deep):170 OMRON INSTRUCTION SHEET. 5mm.
Mechanical automation concept.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication.
Driver programming function.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat OMRON INSTRUCTION SHEET. 3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. Specification: small 3G3MX2-AB001 INSTRUCTION SHEET.
Impact resistance: 120W.
Resistance to impact resistance: 180.
The use of resistance to consume the motor regenerative energy, thereby reducing the time to slow down.
Alarm output terminal of braking resisttor 3G3MX2-AB001 Manual.
When the temperature relay of the braking resistor is activated, a circuit for cutting the main power supply of the frequency converter is formed.