OMRON 3G3MX2-AB022-Z INSTRUCTION MANUAL PDF
Product model: 3G3MX2-AB022-Z
Name: Time lnterval Meter
Brand: OMRON
Sort: INSTRUCTION MANUAL
File language: English
When the power supply capacity exceeds the power supply capacity of the inverter or the need to improve the power factor, it is required to connect the AC reactor 3G3MX2-AB022-Z PDF.
Please according to the maximum capacity of heavy load and light load rated conditions suitable for motor to select option. Optical cable(H-PCF cable).Frequency converter input power: 3 phase AC400V.
Weight: 9.0KG.
Standard applicable line diameter: 60 square mm or more 3G3MX2-AB022-Z
Used to suppress harmonic currents generated by a transducer.
The effect of harmonic current suppression is better than that of AC reactor,
And it can be used with AC reactor 3G3MX2-AB022-Z PDF. Specification: three phase 400V.
Power: 0.4KW.
Maximum output voltage: three phase input voltage.
Rated voltage, frequency: three-phase power supply 380 ~ 50/60Hz, 480V.
Cooling way: natural wind cooling.
Weight: 1.2kg.
Open loop vector control mode of low speed and high torque, rich control function and convenient distribution management network function,
Set in one of the inverter --3G3MZ 3G3MX2-AB022-Z PDF.
3G3MZ series inverter for the application of frequency control and development.
Humanized design and advanced management technology, as well as OMMRON a simple style of modeling, feature rich style,
Combined with the latest technical needs of users, so that it has a noble lineage and the most close to the market elements OMRON INSTRUCTION MANUAL 3G3MX2-AB022-Z Manual.
Covers the special features of the fan pump class, open loop vector function,
Built in noise filter and a variety of network bus,
3G3MZ will be your most economical and the most perfect choice OMRON INSTRUCTION MANUAL. When the power supply capacity exceeds the power supply capacity of the inverter or the need to improve the power factor, it is required to connect the AC reactor.
Please according to the maximum capacity of heavy load and light load rated conditions suitable for motor to select option OMRON INSTRUCTION MANUAL. Specification: three phase 400V.
Power: 45KW.
Maximum output voltage: three phase AC380 ~ 480V (input voltage correspondence).
Rated voltage: three phase 480V ~ 50/60Hz AC380.
Weight: about 36kg.
In the inverter is equipped with the servo can play the same static torque with PG vector control function,
DeviceNet communication makes the application field more extensive.
The high functiional specifications are concentrated in the compact 3G3MX2-AB022-Z INSTRUCTION MANUAL.
Equipped with PG vector control.
Subsequent models of 3G3RV.
CV/VT selection function.
Rich online automatic adjustment function (self learning function).
CX-Drive software. 3G3MX2-AB022-Z Manual.
DeviceNet correspondence correspondence.
Multi function input and output function.
Colorful function.
Brake transistor built-in.
Protection function.