LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Catalog Download
MITSUBISHI QX41-S1 datasheet PDF
Product model: QX41-S1
Name: Type DC input module
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
Express PCI bus.
Support Japanese, English OS.
Master / local station sharing.
Support Ver.2 CC-Link version.
Province distribution network module in cabinet and device.
Link to connect the 64 stations when the fastest scanning time for 1.2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2 QX41-S1 PDF. 5Mbps, 625kbps and 156kbps.
CC-Link/LT from the station does not need any parameter settings QX41-S1
Only need to set up the transmission speed in the master module, you can use the remote I/O.
I/O control in the first class of open field network module.
CC-Link based on reliable field bus technology,
Able to transmit large number of bits data (such as ON/OFF information) and word data (such as analog information) QX41-S1 PDF.
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmission) communication separately, so as to ensure the timeliness of.
Even if the information reaches saturation, it will not affect the link scan time.
Make the mixed data environment intelligent, to achieve a new manufacturing system IE CC-Link field network module QX41-S1 PDF.
Using Ethernet cables and connectors available on the market to reduce costs.
High speed communication capable of communicating with 1Gbps.
Improve the communication response, significantly shorten the cycle time.
Improve the performance of cycle data update. Reduces the transmission delay time and the application of the synchronization waiting time.
Data can be read or written to other station programmable controller.
Status of IE CC-Link field network can be confirmed by Works2 GX.
Can be in the Works2 GX up and down the abnormal position, the cause of the exception, the event record,
So it can reduce the time of abnormal to resume normal operation.Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,).
No heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal station.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the saame time QX41-S1 datasheet.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process QX41-S1 datasheet.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.
Related products
MITSUBISHI
Input module
A1SX40-S1
MITSUBISHI Input module A1SX40-S1
Type of input: DC leakage. Input points:
MITSUBISHI
Input module
AX50-S1
MITSUBISHI Input module AX50-S1
Input points: 16 points. Voltage: DC48V.
MITSUBISHI
Input module
AX31-S1
MITSUBISHI Input module AX31-S1
Input points: 32 points. Voltage: DC24V.
MITSUBISHI
CPU unit
A2SCPU-S1
MITSUBISHI CPU unit A2SCPU-S1
Program memory capacity 14K. Input and o