MITSUBISHI Q173DCPU-S1 Programming Manual (Common Instruction 1/2) PDF
Product model: Q173DCPU-S1
Name: PLC
Brand: MITSUBISHI
Sort: Common Instruction 1/2 Programming Manual
File language: English
Connect to read and write 1Ch.
ID system interface module.
ID controller M-688-001/002 BIS can be installed directly to the Q series of substrates,
Control module for reading and writing ID tag data through a programmable logic controller Q173DCPU-S1 PDF.
The ladder diagram of M-688-002 BIS is compatible with QD35ID1/2.
2 antennas can be connected, and the parallel processing of the 2 channels can be simultaneously carried out Q173DCPU-S1
Can use all ID tags in the M BIS series.
ID series /BIS system is an industrial automation ID system which can use the electromagnetic combination method to read and write data.
ID tag has a variety of sizes and storage capacity Q173DCPU-S1 PDF. Input points: 8 points (dual input), 16 points (single input).
Isolation mode: photoelectric coupling.
Rated input voltage: DC24V.
Output ppoints: 4 points (select the source type + drain type), 2 points (when selecting the source type + source) Q173DCPU-S1 Manual.
Isolation mode: photoelectric coupling Q173DCPU-S1 PDF.
Rated input voltage: DC24V.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards MITSUBISHI Programming Manual.
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outside the standard control procedures MITSUBISHI Programming Manual.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memory,
Output is only when the processing reesult is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down MITSUBISHI Programming Manual Q173DCPU-S1 Programming Manual. AC input: 32 points.
Rated current and voltage: AC100 ~ 120V, 10mA (AC100V, 60Hz).
Ressponse time: 25ms Q173DCPU-S1 Manual.
Input form: 1 points, 32 public ends.
External wiring connections: 38 terminals (terminals sold separately).
Replacement model: AX11.
Related products
MITSUBISHI
CPU unit
Q2ACPU-S1
MITSUBISHI CPU unit Q2ACPU-S1
Input and output points: 1024 points. In
MITSUBISHI
Moving CPU unit
A73CPU-S1
MITSUBISHI Moving CPU unit A73CPU-S1
Multi axis positioning controller. Progr
MITSUBISHI
CPU unit
A2SCPU-S1
MITSUBISHI CPU unit A2SCPU-S1
Program memory capacity 14K. Input and o