LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Manual Download
MITSUBISHI Q172DCPU-S1 PROGRAMMING Guide Book (Structured Text(ST)) PDF
Product model: Q172DCPU-S1
Name: PLC
Brand: MITSUBISHI
Sort: Structured Text(ST) PROGRAMMING Guide Book
File language: English
Master / local station sharing.
Corresponding Ver2 CC-Link.
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmission) communication separately, so as to ensure the timeliness of Q172DCPU-S1 PDF.
Even if the information reaches saturation, it will not affect the link scan time.
The QJ61BT11N module supports CC-Link version 1 and version 2, which can be used as a local station or master station module Q172DCPU-S1
I/O control in the first class of open field network module.
CC-Link based on reliable field bus technology,
Able to transmit large number of bits data (such as ON/OFF information) and word data (such as analog information) Q172DCPU-S1 PDF. Input: 2 channels.
Input: thermocouple / micro voltage / voltage / current.
Conversion speed (input):25ms/2 channel.
Sampling period: 25ms/2 channel.
Output: DC4~20mA.
Conversion speed (output):25ms/2 channel.
18 point terminal station Q172DCPU-S1 PDF.
With 5 kinds of PID control mode.
Loop control module suitable for fast response object control, such as temperature control, flow control, etc..
The loop control module has a PID control format and a sampling period of 25ms that is proportional to the speed,
Support high precision, high resolution Thermocouple Input, micro voltage input, voltage input, current input and current output MITSUBISHI PROGRAMMING Guide Book.
The most suitable for high speed lift and temperature control and pressure control, flow control and other requirements of the application of high speed response Q172DCPU-S1 Manual .
Can be connected with JIS, IEC, NBS, ASTM standard thermocouple MITSUBISHI PROGRAMMING Guide Book.
Through the small voltage, voltage, current input sensor, can be measured in a variety of input range of analog.
Provides the program control function, can according to the specific requirements of the time automatically change the target value (SV) and PID constant [proportional band (P), integration time (I), differential time (D)],
And cascade control function, allowing channel 1 as the main station, channel 2 for the control from the station MITSUBISHI PROGRAMMING Guide Book. Meet safety standards: EN954-1 class 4, 13849-1 PL e ISO.
Safe input points: 1 points (2 input).
Start input points: 1.
Input type: N type (positive public end / negative public end input)
Safe output points: 1 points (3 output).
Spring clip terminal.
Additional security system.
Simply connect to the existing CC-LINK, you can add an independent security features.
Saving wiring by CC-link connectioon Q172DCPU-S1 PROGRAMMING Guide Book.
The wiring is not needed in particular to the condition monitoring of the safety relay module, and realizes the wiring of the cabinet and the other provinces.
Visualization of installation status.
Can monitor the safe output,, as well as the safety input and the internal state of the relay, in the safety circuit to facilitate the identification of the reasons for the start Q172DCPU-S1 Manual .
Related products
MITSUBISHI
CPU unit
A1SCPU-S1
MITSUBISHI CPU unit A1SCPU-S1
Program memory capacity: 8k. Input / out
MITSUBISHI
Motion CPU module
Q172DCPU-S1
MITSUBISHI Motion CPU module Q172DCPU-S1
Upgraded version. Control axis: maximum
MITSUBISHI
CPU unit
A2NCPU-S1
MITSUBISHI CPU unit A2NCPU-S1
Input and output points: 1024 points. In
MITSUBISHI
Motion controller (upgrade)
Q170MCPU-S1
MITSUBISHI Motion controller (upgrade) Q170MCPU-S1
Axis of control: 16. Compact Q170MCPU in