C500-NC Special I/O Unit C/CV Servo Module Single Axis Stepper C500-NC111-V1.CV500-HD SYSMAC BUS PC Unit Hard Disk Drive For 200 VAC CV500-HDD02.OMRON PID Module C500-PID01(3G2A5-PID01-E)For C200H-PRO27-E Hand-held Programming Console ming Console CS1G-CPU42-V1 PDF.
2m.Model: C200HS-MP16K.
Capacity: 16K words/32K words.Name: CS1D CPU Unit for Single CPU Systems.
Specifications: Number of I/O points,
5,120 points (7 Racks);
Program capacity, 250 Ksteps;
Data Memory, 448 Kwords(DM: 32 Kwords,
EM: 32 Kwords×13 banks);
LD execution time, 0
CS1G-CPU42-V102 μs;
Duplex CPUs, --;
Interrupt functions, OK.
Current consumption: 5V system, 0 CS1G-CPU42-V1 PDF. 82A;
26V system, --.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables.
Power supply voltage: DC100V.
Note: operation with output contacts.
Power supply unit.
The power supply of the CPU rack is supplied by the power supply unit CS1G-CPU42-V1 PDF.
The following power units are available for selection.
C200HW-PA204 (vvoltage: AC100-120V/AC200-240V)
C200HW-PA204S (voltage: AC100-120V/AC200-240V)
C200HW-PA204R (voltage: AC100-120V/AC200-240V)
C200HW-PD024 (voltage: DC24V)
In the past, PC connected to a measurement equipment or components must be given to the ASCII unit or BASIC unit to write a communication program OMRON INSTRUCTIONS REFERENCE MANUAL CS1G-CPU42-V1 Manual.
Now, PC C200HX/HG/HE is installed on the communication protocol macro function,
Can be configured to these communications procedures through the PMCR instruction to the ladder program,
With this function system can be easily connected with a wide range of components OMRON INSTRUCTIONS REFERENCE MANUAL. Name: PID Control Module.
Model: C200H-PID02.
Output: Voltage output.C500-IA I/O Unit AC Input 16 pts C500-IA222(3G2A5-IA222).
AC200-240V 10mA.CV500-FH SYSMAC BUS PC Unit Floppy/Hard Disk Drive For 200 VAC CV500-FHD02-E.Name: Two-tier Screw Terminal Block OMRON INSTRUCTIONS REFERENCE MANUAL.
Specifications: Outputs; 16 outputs; PNP.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost cann be reduced CS1G-CPU42-V1 INSTRUCTIONS REFERENCE MANUAL.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CS1G-CPU42-V1 Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.