Model: CPM2C-10C1DT1C-D. CPU Unit: Units with 10 I/O points.
2 Fujitsu connectors.
Inputs: 6 inputs.
Outputs: 4 outputs.
Input type: 24 VDC.
Output type: sourcing transistor CS1G-CPU44-V1 PDF.
Internal clock: Yes.Unit type: CS1 Special I/O Units.
Name: High speed Counter Units.
Specifications: Countable channels,
2; Encoder A and B inputs,
pulse input Z signals, Open collector,
Input voltage: 5VDC,12VDC, or 24VDC,
(only 1 axis for 5 V or 12 V input),
RS-422 line driver;
Max
CS1G-CPU44-V1 counting rate, 50kHz, 500kHz.
No. of unit numbers allocated: 4.
Current consumption: 5V, 0.36A; 26V, --.
Standards: UC, N, L, CE CS1G-CPU44-V1 PDF.
High-Speed, Flexible Control With A,
Wide Array of Features.
Equipped with 2 or 4 Counters and counts,
over a maximum binary range of 32-bits.
Accepting input pulse frequencies of up,
to 500 kHz allows precise control of fast motions.
The Unit is equipped with 4 Digital Inputs,
4 Digital Outputs and 28 Soft Outputs CS1G-CPU44-V1 PDF.
A maximum response time of 0.5 ms guarantees,
high-speed closed loop control of applications. Name: Three-tier Screw Terminal Block.
Specifications: Inputs; 8 inpuuts; NPN;
Without Short-circuit and,
Disconnected Line Detection CS1G-CPU44-V1 Manual.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet OMRON HOST CONNECTION MANUAL.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site OMRON HOST CONNECTION MANUAL.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Unit classification: CJ1 Special I/O Units.
Product name: Highspeed Counter Unit.
Specifications; Countable channels: 2 ,
Encoder A and B inputs, pulse input Z signals;
Open collector Input voltage: 5VDC, 12V, or 24V,
(5V and 12V are each for one axis only OMRON HOST CONNECTION MANUAL. ) ,
Max. counting rate, 50kHz.
No. of unit numbers allocated: 4.
Current consumption: 5V, 0.28A; 24V, --.
Standards: UC1, N, L, CE.
High-Speed, Flexible Control With A,
WWide Array of Features CS1G-CPU44-V1 HOST CONNECTION MANUAL.
Equipped with 2 Counters and counts ,
over a maximum binary range of 32-bits.
Accepting input pulse frequencies of up,
to 500 kHz allows precise control of fast motions.
The Unit is equipped with 2 DDigital Inputs,
2 Digital Outputs and 30 Soft Outputs CS1G-CPU44-V1 Manual.
A maximum response time of 0.5 ms guarantees,
high-speed closed loop control of applications.