Cable length: 5 m.
The highest level of ionization in its class.
Sensing and variable-AC system provides fast and meticulous ionization.
Linked Ionizers cover a wide area without causing uneven ionization.
Digital ion display provides simple and reliable settings.
Time specification: Inverse type.
Current setting range: 50 to 160 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage OMRON ZJ-BAS-FC05A.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase
ZJ-BAS-FC05A
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions OMRON ZJ-BAS-FC05A. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Rated input (See note 2.): 3-phase 3-wire mode, 3-phase 4-wire mode;
380, 400, 415, 480 VAC, 220, 230, 240, 277 VAC.
Ideal for monitoring 3-phase power supplies OMRON ZJ-BAS-FC05A.
for industrial facilities and equipment.
Monitor overvoltages and undervoltages for three-phase 3-wire,
or 4-wire power supplies.
DIP switch setting for 3-phase 3-wire or 3-phase 4-wire power supply ZJ-BAS-FC05A OMRON.
Two SPDT output relays, 6 A at 250 VAC (resistive load).
Separate outputs possible for overvoltages and undervoltages.
World-wide power specifications supported by one Unit,
(switchable using DIP switch) ZJ-BAS-FC05A OMRON.
Relay status can be monitored using LED indicator. Servo trunk unit.
Product Name: servo relay unit.
Application unit: CJ1M-CPU21/22/23.
Specifications: -.
Axis number: single axis.
The connector and terminal of the relay unit are integrated into a whole,
Save the wiring servo drive and position control unit ZJ-BAS-FC05A OMRON.
Servo driver and conntrol signal of position control unit,
Simple wiring on terminal stage ZJ-BAS-FC05A.
The connector without soldering, with only a screwdriver can wiring.
Dedicated connection cable between units.
DIN guide rail installation, the rapid installaation, screw installation of two methods OMRON ZJ-BAS-FC05A.
M3.0 thread terminals attached with a special plate signal.
The terminal can be confirmed by the signal name.