Cable length L: 2.0 m.
Controllers with one touch.
Mounted Connector: XG4C MIL Connectors.
No. of poles: 40.
Dimension A: 149.
Dimension B: 110.
Mounted Connector model: XG4C-4031.
Cable Connector model: XG4M-4030-U.
New Slim Connector-Terminal Block,
Conversion Units.
Mounting area reduced by 35% (in comparison with,
40-pole XW2B Units) to contribute to downsizing,
control panels and automatic equipment OMRON XW2Z-200H-1.
Fallout prevention for terminal screws
XW2Z-200H-1
Round or forked crimp terminals can be used.
Mount to DIN Track or via screws.
Unique DIN Track lock can maintain open status,
during DIN Track attachment and removal.
Terminal cover can be locked open.
Screw terminals are arranged by color in groups,
of five to simplify counting terminal numbers OMRON XW2Z-200H-1. Rated voltage: 115 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.200 A; 60 Hz, 0.180 A.
Rated input: 50 Hz, 15 W ; 60 Hz, 14 W .
Rated rotational speed: 50 Hz, 2,750 r/min; 60 Hz, 3200 r/min.
Maximum flow rate: 50 Hz, 2.7 m3/min; 60 Hz, 3.1 m3/min.
Maximum static pressure: 50 Hz, 93.1 Pa; 60 Hz, 99.0 Pa.
Noise: 50 Hz, 42 dB; 60 Hz, 46 dB OMRON XW2Z-200H-1.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation XW2Z-200H-1 OMRON.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series XW2Z-200H-1 OMRON.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. Power supply voltage: 100 to 240 VAC XW2Z-200H-1 OMRON.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phhase control, and cyclic control XW2Z-200H-1.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads OMRON XW2Z-200H-1.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).