XS3R-M426-1C51-A OMRON XS3R-M426-1C51-A
Brand: OMRON
Name: Round Water-resistant Connectors
Model: XS3R-M426-1C51-A
Cable: With cable.
Connector: Connectors on both cable ends.
Cable length L: 0.5 m.
Minimum order: 5.
Small Round Water-resistive.
Connectors.
Water-resistive, compact connector meets IP67 requirements.
Conventional M8 screw-mounting models are available along with,
S8 snap-in models that connect and disconnect with one touch.
Ideal for a wide variety of FA and OA applications.
Connectors on both cable ends require no harness work.
Some new M8 models with 3 or 5 poles.

Configuration: Covered Power Supplies.
Input voltage: 100 to 240 VAC (free) (80 to 370 VDC *).
S8JX-G15005@@:Switchable between 100 to 120 VAC and 200 to 240 VAC.
(DC power cannot be input.).
Power ratings: 35 W.
Output voltage: 48 V.
Output current: 0.75 A.
Built-in fan: No.
Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 48 V) OMRON XS3R-M426-1C51-A.
Easy Mounting: Front-mounted type, DIN rail-mounted type are available XS3R-M426-1C51-A
Screw-mount at the top. (except 300-/600-W models).
Safety standards: UL 508/60950-1, cUL CSA C22.2 No. 107.1,
cUR CSA C22.2 No. 60950-1.
EN 50178 (= VDE 0160) Over voltage.
category III.
EN 60950-1 (= VDE 0805 Teil 1).
EMC: Conforms to EN 61204-3.
(EMI:EN55011 ClassA) OMRON XS3R-M426-1C51-A.
Input conditions: The input voltage range of 15-W, 35-W,
50-W, 100-W, and 150-W models has,
been increased to 80 to 370 VDC (EC Directives and safety standards do not apply.).Item: Humidity Sensor (3 m).
Easy-to-use and Compact 10-Channel Logger,
with Internal 4 GB Flash Memory. Time specification: Instantaneous type.
Current setting range: 50 to 160 A.
Operating voltage: 100/110/120 VAC OMRON XS3R-M426-1C51-A.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Power ratings: 480 W.
Input voltage: Single phase, 100 to 240 VAC, 90 to 350 VDC.
Output Voltage: 24 V.
Output current *1: 20 A.
Cost-effective Single Phase Power Supply.
Universal input and Safety standards.
for worldwide applications.
Space-saving Compact Design.
Universal input for worldwidee applications:
100 to 240 VAC (85 to 264 VAC) XS3R-M426-1C51-A.
DC input can be available: 90 to 350 VDC.
Operation temperature range: –25 to 60 °C.
Compact Dimension for small space.
Flexible installation by special mounting brackets.
Safetyy standards:
UL508/60950-1, CSA C22 XS3R-M426-1C51-A. 2 No.107.1/60950-1.
EN50178, EN60950-1.
EMS: Conform to EN61204-3.
EMI: EN55011 Class A.
Three years Warranty.


...More relevant models >>>>