Transistor output module (source) LY42PT1P-CM MITSUBISHI LY42PT1P-CM
Brand: MITSUBISHI
Name: Transistor output module (source)
Model: LY42PT1P-CM
Output points: 64 points.
Output form: source type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have.
Common way: 32 point / public end.
Input / output occupied points: 64 points (I/O distribution: output 64 points).
External wiring connection: 40 pin connector two.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called.
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch.
Communication protocol is a standard Modbus protocol or custom protocol.

Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Can be isolated to obtain DC24/48/100V, AC100/200V input signal.Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output MITSUBISHI LY42PT1P-CM. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output LY42PT1P-CMNumber of input channels: 8ch.
Input voltage: DC - 10 ~ 10V.
Conversion speed: 1ms/ch.
Resolution: 1/16000.
By shifting the function easily when the system starts to fine tune the movement function.
Shift the set value to (shift to) the function of the digital output value MITSUBISHI LY42PT1P-CM.
If you change the conversion value, the value is reflected in real time to the value of the scale (numeric value),
Can easily complete the fine-tuning of the system startup.
Extended detection method based on usage
Anomaly detection and extension of input signal
The detection method of the abnormal detection function of the input signal can be extended to detect the abnormal detection function of the input signal which is outside the range of the set range MITSUBISHI LY42PT1P-CM.
For the detection of the lower limit or the upper limit of the input signal abnormality, or when the detection of the broken line is performed LY42PT1P-CM MITSUBISHI.
Enter range extension
Range of scalable input range.
Combined with the abnormal detection function of the input signal, the broken line can be easily detected LY42PT1P-CM MITSUBISHI. Output points: 16 points.
Rated output voltage: DC24V/AC240V.
Rated open and close current: 2A/1 point.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: output 16 points).
External wiring connection: 18 point terminal LY42PT1P-CM MITSUBISHI.
The switch input and output module is a device which can collect the input / outputt of the switch signal,
Digital I/O modules are often called LY42PT1P-CM.
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can alsso be carried out through the RS-485 bus communication,
Remote control switch MITSUBISHI LY42PT1P-CM.
Communication protocol is a standard Modbus protocol or custom protocol.