LK Automation Limited LK Automation Limited
Brand: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Go Back >> Product Catalogues
S87A-11N OMRON Power failure detector
Brand: OMRON
Name: Power failure detector
Model: S87A-11N
Type: 1 output.
Input power: 100/110/120V AC.
Detection, output form: voltage drop, power failure.
Power supply (commercial AC power supply) power cut detector for monitoring and control device.
Instantaneous detection voltage drop, power failure, instantaneous power failure.
Small, easy to install DIN guide rail mounting type.
Input voltage is divided into AC100V, AC200V two specifications.

Power ratings: 15 W.
Output voltage: 48 V.
Output current: 0.32 A.
Boost current: --.
Newly Released High-capacity 240-W Models in S8EX-series Lineup.
Rated Output of 300 W for 200 VAC.
From 170 to 264 VAC.
New 240-W Models.
Lineup of models with 24-, 36-, and 48-VDC output.
voltages.
15-W, 35-W, 50-W, 100-W, and 150-W Models S87A-11N OMRON.
Lineup of models with from 5 to 48-VDC output S87A-11N
voltages.
All Models.
Approved standards:
UL60950-1, cUR CSA C22.2 No. 60950-1, EN 50178,
and EN 60950-1.
Lineup includes open-frame models, models with.
chassis, and models with chassis and covers.
Wide-range power supply: 100 to 240 VAC.
Complies with harmonic current standard in EN.
61000-3-2 (50-W to 240-W models) S87A-11N OMRON.
The top class in industry for compact size.
Boost current output (some models excluded). Type: cable connector socket.
Contact number: 4.
Wiring simple and e-CON * specifications for connectors;
Ideal choice for connecting sensors.
The connection of the spring clip which is verified by the industry is adopted.
Wiring is simple, no special tools required,
Can be re wiring (maintenance) S87A-11N OMRON.
Acceptable range for each connector
Stranded AWG28 (0.08mm2) ~ AWG20 (0.5mm2),
Any core wire size between.
(outer diameter: no more than 1.5mm).
A clamp capable of simultaneously connecting 4 lines when a connection is also provided.
UL standard (Document No. E103202) identified as a standard product.
Cable connector with the UL standard certification of products.
"
Model: OFR (95H).
Protection of distributed power supply connection to power system,
The relay is smaller, and the protection unit is more enriched.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular.
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system.
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system.
Can also correspond to the generator and the electric side // internal tributaries S87A-11N.
Unit with 2 relay elements.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determiine the direction of the sudden drop in the voltage to 0 of the short-circuit accident S87A-11N.
2 stage cross terminal stand with cover with convenient wiring.


...More relevant models >>>>
Last one: OMRON S87A Series
next one: OMRON S87A-12N