Rated voltage: 100 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2650 r/min; 60 Hz, 3000 r/min.
Maximum flow rate: 50 Hz, 2.4 m3/min; 60 Hz, 2.7 m3/min.
Maximum static pressure: 50 Hz, 68 Pa; 60 Hz, 63 Pa.
Noise: 50 Hz, 49 dB; 60 Hz, 52 dB.
Weight: Approx. 2260 g.
Easy One-step Mounting.
simplify installation work.
convenience in confined spaces.
mounting screws).
Optional Replacement Filter and Vent Attachment.
metal blades.
Control power supply voltage: 125 VDC.
Input: DC or AC (selectable), Input voltage range, 10 to 300 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL) R87B-TA1A15HPF2 OMRON.
Detect three-phase AC current for under and/or overcur,
rent using current converter
R87B-TA1A15HPF2
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F) R87B-TA1A15HPF2 OMRON.
LED operation indicator.
UL/CSA approval (SDV-F@). Type: open type.
Structure: DIN guide rail mounting type.
Capacity: 15W.
Output voltage: 5V.
Output current: 3A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function R87B-TA1A15HPF2 OMRON.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
Power supply voltage: 100 to 240 VAC.
Ideal for Liquid Level Control in.
Industrial Facilities and Equipment.
Self-holding circuit implemented with circuit processing that is,
not depending onn external wiring R87B-TA1A15HPF2.
Switch between water supply and discharge with a DIP switch setting.
Sensitivity adjustment of operating resistance from 10 k to 100,
kΩ for application to a wide range of liquids.
Prevents chattering of relay contacts that occurs with ripples R87B-TA1A15HPF2.
Easy wiring with ferrules.
Use 2 × 2.5 mm2 solid wire or 2 × 1.5 mm2 ferrules.
Applicable as a floatless switch.