LK Automation Limited LK Automation Limited
Brand: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Go Back >> Product Catalogues
R87B-FA6A15LPFR2 | OMRON Box Fan R87B-FA6A15LPFR2
Brand: OMRON
Name: Box Fan
Model: R87B-FA6A15LPFR2
Rated voltage: 230 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2100 r/min; 60 Hz, 2200 r/min.
Maximum flow rate: 50 Hz, 2.0 m3/min; 60 Hz, 2.1 m3/min.
Maximum static pressure: 50 Hz, 47 Pa; 60 Hz, 44 Pa.
Noise: 50 Hz, 45 dB; 60 Hz, 46 dB.
Weight: Approx. 2220 g.
Comprehensive Lineup of Single,
Double, and Triple Axial Fans with,
Easy One-step Mounting.
Mounts in a square cutout and conceals the hole-cut to,
simplify installation work.
Cover can be set to open either upward or downward for,
convenience in confined spaces.
Enhanced accessories (finger guard, filter, plug cord,
mounting screws).
Optional Replacement Filter and Vent Attachment.
The lineup includes Single, Double, and Triple Box Fans,
with eight models with plastic blades and eight models with,
metal blades.

Power ratings: 240 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*1).
Output voltage: 24 V.
Output current: 10 A.
Alarm output *2: Sinking.
UL Class 2 Output standards: --.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication OMRON R87B-FA6A15LPFR2.
Monitor and Simple Functions for.
Easy System Commissioning R87B-FA6A15LPFR2
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1) OMRON R87B-FA6A15LPFR2.
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.) Type: open type.
Structure: bottom mounting type.
Capacity: 100W.
Output voltage: 12V.
Output current: 8.5A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function OMRON R87B-FA6A15LPFR2.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products R87B-FA6A15LPFR2 OMRON.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage R87B-FA6A15LPFR2 OMRON.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer R87B-FA6A15LPFR2 OMRON. )
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
Ideal to prevent heater overheating.
Self-latching output to contribute to safe,
equipment operation.
Set the temperature with ultra-simple rotary switches.
Digitally set the temperature to between 0 and 999°C in 1°C increments with one,
Relay (K8DT-TH1@@).
(K8DT-TH2@@: Set to between 0 and 1,800°C in 10°C increments.).
Connect a thermocouple or platiinum resistance thermometer R87B-FA6A15LPFR2.
Width of 17.5 mm to reduce space required in panels.
Push-In Plus Terminal that reduce wiring work.
The use of cage clamps enables wiring with bare stranded wires.
Double-insertion holes for crrossover wiring (all terminals) OMRON R87B-FA6A15LPFR2.
UL listed for easy shipping to North America.
Models added with transistor outputs for superior contact reliability.


...More relevant models >>>>