LK Automation Limited LK Automation Limited
Brand: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Go Back >> Product Catalogues
R60AD8-G Analog input module MITSUBISHI R60AD8-G
Brand: MITSUBISHI
Name: Analog input module
Model: R60AD8-G
Analog input channel number: 8CH.
accuracy
Ambient temperature of 25 plus or minus 5 degrees C: plus or minus 0.1%.
Ambient temperature 0 ~ 55 degrees C:-.
Temperature coefficient: positive and negative 35ppm/.
Common
Conversion speed: 10ms.
Insulation between channels: isolation transformer insulation.
Absolute maximum input: positive and negative 15V, 30mA.
External wiring connection mode: 40 pin connector.
Voltage input
The analog input voltage: DC - 10 - 10V.
Digital output value: 32000 ~ 32000.
Current input
Analog input current: DC0 ~ 20mA.
Digital output value: 0 ~ 32000.
Analog input module for the external analog signal into the interface of the programmable controller.
Can choose the channel between the insulation, voltage input, current input, voltage / current mixed input, thermocouple input, temperature resistance (RTD) input for a variety of purposes, such as modules.
Filter high frequency interference.
Analog input module has been equipped with a first order lag filter.
The analog input signal with high frequency interference component can be obtained by using the first order lag filter.
Parameters can be set through the filter time constant, no program can be easy to use.
Execute event driven program through alarm output
Strengthen the implementation of the interrupt function according to the alarm output flag, easy to carry out preventive maintenance.
The measured value and the change rate of the analog input signal exceed the upper and lower limits of the set,
Regardless of the procedure of the scan time, can be executed interrupt handling, quickly respond to abnormal conditions.

Analog input channel number: 8CH.
Cold end compensation precision.
Available thermocouple: -.
Available temperature resistance: Pt100, JPt100, Ni100, Pt50.
Resolution: 0.1.
Conversion speed: 10ms/CH.
Insulation between channels: isolation transformer insulation.
Disconnection detection: there.
External wiring connection mode: 40 pin connector MITSUBISHI R60AD8-G.
output
The temperature measurement value (16 bit''signed binary): 2000 ~ 8500 R60AD8-G
Zoom value (16 bit with symbol binary).
No program can perform conversion operations, scaling
Easy to use parameters to set the conversion operation and scaling, no need to create a dedicated program.
Therefore, it is helpful to reduce the development cost of the program and to reduce the program capacity MITSUBISHI R60AD8-G.
High speed data sampling is not affected by the scan time.
The analog input module has the function of recording, which can be used to collect the analog quantity input data in the industrial application.
Can continuously collect data in a set period, each channel can store up to 10000 points of the recorded data.
In addition, the state of the state of any time and data in the program can be changed as a trigger,
To stop collecting data MITSUBISHI R60AD8-G. The analog quantity input data can be stored and maintained before and after the trigger state through the function,
Easy to determine the occurrence of the phenomenon and the collection of test data R60AD8-G MITSUBISHI. Such as motor testing equipment used in this function.
Control instructions from a programmable controller to a transducer and a power meter transmission test mode,
At the same time, the test data of the test motor is collected at the same time R60AD8-G MITSUBISHI. Analog output channel number: 8CH.
accuracy
Ambient temperature of 25 plus or minus 5 degrees C: plus or minus 0.1%.
Ambient temperature 0 ~ 55 degrees C:- R60AD8-G MITSUBISHI.
Temperature coefficient: positive and negative 50ppm/.
Conversion speed: 1ms/CH.
Insulation between channels: isolation transformer insulation.
Output short circuit protection: have.
External power supply: -.
External wiring connection mode: 40 pin connector.
Voltage output
Digital input value: 32000 ~ 32000.
Analog output voltage: DC - 10 - 10V.
Current output
Digital input value: 0 ~ 32000.
Analog output current: DC0 ~ 20mA.
High speed output flow simulation waveform.
The analog output module has the function of registering arbitrary waveform data to the module, and continuously executing the analog output according to the set conversion cycle.
Execute the analog quantity (torque) control of stamping machine and injection molding machine, can automatically output the control waveform,
Through the process of high speed, smooth control. In addition, only prior to the waveform data are registered in the module,
Can easily control the aanalog waveform, so the production line control, such as repetitive control,
Without using a special program to create the waveform, can reduce the programming time R60AD8-G.
Easy to use parameters to set the conversion operation and scalling, no need to create a dedicated program MITSUBISHI R60AD8-G.
Therefore, it is helpful to reduce the development cost of the program and to reduce the program capacity.


...More relevant models >>>>