LK Automation Limited LK Automation Limited
Brand: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Go Back >> Product Catalogues
R60AD4 | MITSUBISHI R60AD4 Analog input module
Brand: MITSUBISHI
Name: Analog input module
Model: R60AD4
Analog input channel number: 4CH.
accuracy
Ambient temperature of 25 plus or minus 5 degrees C: plus or minus 0.1%.
Ambient temperature 0 ~ 55 degrees C: plus or minus 0.3%.
Temperature coefficient.
Common
Conversion speed: 80 s/CH.
Channel to channel insulation.
Absolute maximum input: positive and negative 15V, 30mA.
External wiring connection mode: 18 point screw terminal.
Voltage input
The analog input voltage: DC - 10 - 10V.
Digital output value: 32000 ~ 32000.
Current input
Analog input current: DC0 ~ 20mA.
Digital output value: 0 ~ 32000.
16 bit high resolution (1/32000).
No program can perform scaling and conversion operations.
The most suitable for the requirements of speed and accuracy of the detection equipment.
Easy to filter high frequency interference.
Execute event driven programs via alarm output.
Through the engineering software, the output of arbitrary analog waveform data.
Channel insulation.
Similar to the input and output modules, analog quantity module is the interface between the sensor and the programmable controller.
The difference between the input and output modules is that it is dealing with analog voltage and current signals rather than ON/OFF signals.
The analog module MELSEC iQ-R series is equipped with high-speed conversion (80 s/CH), high resolution (1/32000), channel insulation, abnormal signal detection and other convenient features,
Can achieve high precision analog control.

Differential input, transistor (drain type) output.
Channel number: 2CH.
External wiring connection mode: 40 pin connector
Count input signal: there
Single phase input (single frequency / double frequency)
Dual phase input (single frequency and double frequency /4)
CW/CCW input: there
The signal level (phi A, Phi B): EIA standard RS-422-A differential line driver level MITSUBISHI R60AD4.
PWM output function can be output through the highest frequency of 200kHz, minimum ON 100ns width of the PWM waveform of any duty cycle R60AD4
In addition, the output cycle and duty cycle can be changed when the output PWM,
The use of the most suitable for the use of continuous PWM signal flow control. Safety grade (SIL): SIL 3 (IEC 61508) MITSUBISHI R60AD4.
Performance level (PL): e PL (13849-1 EN/ISO).
Operation control mode: stored procedures repeated operation.
Program capacity: 1200K (security program: 40K).
Program memory: 4800K.
Soft element / tag memory: 3370K.
Data memory: 40M.
Unified program development environment.
Whether the general control procedures or safety control procedures, can be integrated into 1 Engineering documents,
Unified management by Works3 GX MITSUBISHI R60AD4. The troublesome operation can save more than one project file management.
When you create a security control program, you are also the same as when you create a general control program,
Various features of GXWorks3 can be developed using the support program R60AD4 MITSUBISHI.
Improve production efficiency through high responsiveness and rich program capacity.
Efficient use of high performance iQ-R CC-Link series and IE Field MELSEC networks,
Improve responsiveness and improve production efficiency R60AD4 MITSUBISHI.
In addition, the security control program capacity increased to 40K, about 3 times in the past.
Safe CPU can be used to deal with complex large capacity programs R60AD4 MITSUBISHI. Analog output channel number: 8CH.
accuracy
Ambient temperature of 25 plus or minus 5 degrees C: plus or minus 0.1%.
Ambient temperature 0 ~ 55 degrees C: plus or minus 0.3%.
Temperature coefficient.
Conversion speed: 80 s/CH.
Channel to channel insulation
Output short circuit protection: have.
External power supply: DC24.
External wiring connection mode: 18 point screw terminal.
Voltage output
Digital input value: 32000 ~ 32000.
Analog output voltage: DC - 10 - 10V.
Current output
Digital input value: -.
Analog output current: -.
High speed output flow simulation waveform.
The analog output module has the function of registering arbitrary waveform data to the module, and continuously executing the analog output according to the set conversion cycle.
Execute the analog quantity (torque) control of stamping machine and injection molding machine, can automatically output the control waveform,
Through the process of high speed, smooth control. In addition, only prior to the waveform data are registered in the module,
Can easily control the analog waveform, so the production line control, such as repetitive control,
Without using a special program to create the waveform, can reduce the programming time R60AD4.
The analog output module is the interface of analog signal to the external output througgh the programmable controller MITSUBISHI R60AD4.
Can choose voltage output, current output, voltage / current mixed output type for a variety of purposes of the module.