Incrementing/decrementing C/F (phase difference inputs).
Mounting method: Flush mounting.
Operation modes: N, F, C, R, K, P, Q (selectable with rotary DIP switch).
Input signal method (Count and reset inputs): Contact and transistor input, voltage (H and L).
(H and L output switchable).
Set value read: Continuous mode.
Memory backup: No .
Display: Yes (10-mm high 7-segment LED, Up indicator).
Models: 4 digits; 2 stages.
A DIN 72 x 72 mm Best-selling Counter.
Easy setting with thumbwheel switches.
A draw-out construction enables maintenance without rewiring.
Models with 2-, 4-, 6-, or 8-digit displays are also available.
Total Counter models are also Available.
Complies with UL and CSA Marking.
Operating method: Reversible (selectable with rotary DIP switch) between,
0 and the full scale; Incrementing/decrementing A/D (command inputs);
Incrementing/decrementing B/E (individual inputs);
Incrementing/decrementing C/F (phase difference inputs).
Mounting method: Flush mounting.
Input signal method (Count and reset inputs): Contact and transistor input, voltage (H and L) OMRON H7AN-WE4D
H7AN-WE4D
Memory backup: Yes/No (Selectable using DIP switch).
Display: Yes (10-mm high 7-segment LED).
Models: 4 digits.
A DIN 72 x 72 mm Best-selling Counter.
Easy setting with thumbwheel switches.
A draw-out construction enables maintenance without rewiring.
Models with 2-, 4-, 6-, or 8-digit displays are also available OMRON H7AN-WE4D.
Total Counter models are also Available.
Complies with UL and CSA Marking. Category: external supply 100mA DC5V type.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
No output: -.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified OMRON H7AN-WE4D.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Can enter DC0.001mV toType: H5CX-L series.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2 H7AN-WE4D.
External connections: 8-pin socket.
Input: SSignal, Reset (NPN input) H7AN-WE4D.
Output: Transistor output(SPST).
Supply voltage: 12 to 24 VDC/24 VAC.
The Timer with the Shortest Body,
in the Industry.