LK Automation Limited LK Automation Limited
Brand: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Go Back >> Product Catalogues
LY42NT1P-CM MITSUBISHI LY42NT1P-CM
Brand: MITSUBISHI
Name: Transistor output module (drain type)
Model: LY42NT1P-CM
Output points: 64 points.
Output type: leakage type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have.
Common way: 32 point / public end.
Input / output occupied points: 64 points (I/O distribution: output 64 points).
External wiring connection: 40 pin connector two.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called.
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch.
Communication protocol is a standard Modbus protocol or custom protocol.

Output points: 32 points.
Output type: leakage type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have.
Common way: 32 point / public end.
Input / output occupied points: 32 points (I/O distribution: output 32 points).
External wiring connection mode: 40 pin connector MITSUBISHI LY42NT1P-CM.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called LY42NT1P-CM
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch.
Communication protocol is a standard Modbus protocol or custom protocol MITSUBISHI LY42NT1P-CM. IE Field CC-Link intelligent equipment station.
Transmission speed: 1Gbps.
Remote input / output: 2048 points.
Remote register: 1024 words.
RAS function.
End cap.
Play the role of IE CC-Link field network remote station
Can be installed in the IE CC-Link field network host module L series of a variety of I/O module, intelligent function module MITSUBISHI LY42NT1P-CM.
Can be used as the remote station of IE CC-Link field network,
The flexible configuration of I/O module and intelligent function module is realized,
Reduce device wiring, save space.
Management of abnormal information through the RAS function
An error occurred in the remote station,
After the error record is saved to the IE CC-Link field network host module''s latch area,
Instantaneous notification to the master station via the network.
Even if the power of the system is cut off, the error record in the locked area is still retained,
So it is easy to determine the location of the problem, to maximize the reduction of downtime. Can be used to locate the wiring between drives.
Trunk terminal available for external input signal. Convert connectors to fast connectors.
According to the location of the connection equipment distribution module. DC input.
Number of input channels: 2Ch.
DC5/12/24V input.
Maximum count rate: pulse/s 200k.
Linear counter function.
Ring counter function.
Uniform output function.
Preset function.
Count invalid function.
Latch counter function.
Sampling counter function.
Periodic pulse counter function.
Flexibly applied to various applications
Combination of functions,
Easy to achieve speed measurement, long measuring function, the single pulse output, the ratio of the set / distribution output, PWM control, cam switch control, such as a wide range of control.
Single pulse.
To trigger the input as a starting point, with a minimum 25ns unit to adjust the ON/OFF time.
The action time deviation of ON/OFF is ns level, so it can achieve high precision conntrol LY42NT1P-CM.
Velocity measurement and length measurement
In addition to the measurement of ON width and OFF width,
Can also achieve different sensor ON time difference and other conditions of the measurement.
The high precision measurement of the smallest 25ns unit can be realized LY42NT1P-CM.
Delayed output
The output time delay of each channel can be adjusted so that the error output can be realized.


...More relevant models >>>>