L6DSPU-C-CM MITSUBISHI L6DSPU-C-CM
Brand: MITSUBISHI
Name: Display module
Model: L6DSPU-C-CM
Display characters: 16 x 4 character line width.
Display character: English letters and numbers (full / half), Katakana (full / half), hiragana (angle), (angle), symbol Chinese characters (full / half).
Language switch: Chinese / english.
Backlight display: green (normal), red (abnormal).
Weight 0.03kg.

Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Can be used as a screw relay terminal.DC5V internal consumption current: 0.08A.
Weight: 0.13kg MITSUBISHI L6DSPU-C-CM.
1 the field input interface module is composed of an optical coupling module and an input interface module of the microcomputer,
Function is the interface of the programmable logic controller and the field control L6DSPU-C-CM
2 the field output interface module is integrated with the output data register, the gating module and the interrupt request module,
The programmable logic controller outputs the corresponding control signal to the execution part of the field through the field output interface module MITSUBISHI L6DSPU-C-CM. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Convert connector to screw relay terminal.
According to the location of the connection equipment distribution module. Number of input channels: 8ch.
Input temperature resistance: Pt1000, Pt100, JPt100, Pt50, Ni500, Ni120, Ni100, Cu100, Cu50 MITSUBISHI L6DSPU-C-CM.
Conversion speed: 40ms/ch.
Resolution: 0.1.
Status of connected devices by means of alarm monitoring.
Alarm output function
Process alarm.
When the digital value is in the range of preset, the output alarm.
Change rate alarm.
The output value of the output value of the digital output is too large (greater than the rate of change of the alarm limit) or too small (less than the rate of change), the output alarm.
Achieve stability measurement
Inter channel isolation
Isolation between the channels, can prevent the connection of sensors in the channel between the cross talk, so as to achieve stable measurement.
High speed, smooth conntinuous analog output L6DSPU-C-CM.
Waveform output function
Equipped with the industry''s first waveform output function.
The pre prepared waveform data can be imported into the analog output module, and the function of the analog output is simulatted according to the set conversion period L6DSPU-C-CM.
It is not affected by the sequential scan time, and it can realize the high speed and smooth analog output.