LK Automation Limited LK Automation Limited
Brand: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Go Back >> Product Catalogues
K8AC-H21CC-FLK Digital Heater Element Burnout Detector OMRON K8AC-H21CC-FLK
Brand: OMRON
Name: Digital Heater Element Burnout Detector
Model: K8AC-H21CC-FLK
Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).

Power ratings: 480 W.
Input voltage: 100 to 240 VAC.
Output voltage: 24 V.
Output current: 20 A Peak current 30 A (200 VAC).
UL Class 2 Output standards: --.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning OMRON K8AC-H21CC-FLK.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards K8AC-H21CC-FLK
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC OMRON K8AC-H21CC-FLK.
(Not compliant with EC Directives and other safety standards.) Rated voltage: 230 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.052 A; 60 Hz, 0.045 A .
Rated input: 50 Hz, 12 W ; 60 Hz, 10 W .
Rated rotational speed: 50 Hz, 1700 r/min; 60 Hz, 2000 r/min.
Maximum flow rate: 50 Hz, 1.3 m3/min; 60 Hz, 1 OMRON K8AC-H21CC-FLK. 5 m3/min.
Maximum static pressure: 50 Hz, 19.6 Pa; 60 Hz, 23.5 Pa.
Noise: 50 Hz, 32 dB; 60 Hz, 34 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment K8AC-H21CC-FLK OMRON.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series K8AC-H21CC-FLK OMRON.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards dependd on the,
product K8AC-H21CC-FLK. Check the information given for available models of Axial fans and,
the information in Characteristics K8AC-H21CC-FLK OMRON. Cable with connector (1 to 2) /G79-O_C-_, G79-I_C-_.
L size: A, 2000mm; B, 1750mmm OMRON K8AC-H21CC-FLK.
Input use.
Cable and loose wire cable with loose wire pressing connecting terminal,
Connector cable, MITSUBISHI motor produced PLC connection cable.


...More relevant models >>>>