Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display.
External event input can be applied to a variety of measurement and identification situations.
Operating method: Incrementing, decrementing, and reversible (UP/DOWN A to F).
Mounting method: Flush mounting.
Input signal method (Count and reset inputs): Contact and transistor input, voltage (H and L).
Memory backup: No.
Display: Yes (8-mm high 7-segment LED).
Models: 8 digits.
A DIN 72 x 72 mm Best-selling Counter OMRON K3HB-XAA-L1AT11 AC/DC24.
Easy setting with thumbwheel switches.
A draw-out construction enables maintenance without rewiring
K3HB-XAA-L1AT11 AC/DC24
Models with 2-, 4-, 6-, or 8-digit displays are also available.
Total Counter models are also Available.
Complies with UL and CSA Marking. Supply voltage: 24, 100 to 120, 200 to 230 VAC;
12, 24, 48, 100 to 110, 125 VDC.
Time-limit contact: 4PDT.
Long-time range model(0 OMRON K3HB-XAA-L1AT11 AC/DC24. 1 min to 10 h).
Miniature Timer with Multiple Time.
Ranges and Multiple Operating Modes.
Minimizes stock.
Pin configuration compatible with MY Power Relay.
Standard multiple operating modes and multiple time ranges.
Conforms to EN 61812-1 and IEC 60664-1 for Low Voltage,
and EMC Directives. Supply voltage: 24 VAC; 12, 24 VDC.
Time-limit contact: DPST-NO.
Long-time range model (0 OMRON K3HB-XAA-L1AT11 AC/DC24. 1 min to 10 h).
Ultra-slim Timer for G2R Relay Socket.
Pin configuration compatible with G2R Relay and mounts to the,
P2R/P2RF Socket.
Standard multiple time ranges and multiple operating modes.
Conforms to EN61812-1 and IEC60664-1 4 kV/2 for Low Volt,
age, and EMC Directives. Supply voltage: 24 to 240 VAC/DC.
Control output: Contact output, SPDT (time-limit SPDT).
Eight-mode Timer.
Multiple time ranges and operating modes let you cover a wide,
range of applications.
The time-limit DPDT output contacts can be changed to time-limit,
SPDT and instantaneous SPDT output contacts using a switch.
Sequence checks are easily performed by setting an instanta,
neous output to 0.
Start signal control for the H3DK-M. Supply voltage: 24, 100 to 120, 200 to 230 VAC; 12, 24, 48, 100 to 110, 125 VDC.
Time-limit contact: 4PDT.
Short-time range model (0.1 s to 10 min).
Miniature Timer with Multipple Time Ranges,
and Multiple Operating Modes K3HB-XAA-L1AT11 AC/DC24.
UL listed when used with a Push-In Plus Terminal Block Socket.
Conforms to CSA, CE Marking, LR, and CCC.
Black design with power supply terminals on top and contact output,
terminals on bottom K3HB-XAA-L1AT11 AC/DC24.
Standard multiple operating modes and multiple time ranges.
Pin configuration compatible with MY Power Relay.
Minimizes stock.