Time specification: Instantaneous type.
Current setting range: 8 to 26 A.
Operating voltage: 400/440 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
rent, open-phase, and reverse-phase.
ing the test button.
is indicated from the start of operation.
Space-saving, integrated construction.
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Power ratings: 30 W.
Output voltage: 24 V.
Output current: 1.3 A.
Boost current: --.
Newly Released High-capacity 240-W Models in S8EX-series Lineup.
Rated Output of 300 W for 200 VAC.
From 170 to 264 VAC.
New 240-W Models.
Lineup of models with 24-, 36-, and 48-VDC output.
voltages.
15-W, 35-W, 50-W, 100-W, and 150-W Models K2CM-Q4L OMRON.
Lineup of models with from 5 to 48-VDC output
K2CM-Q4L
voltages.
All Models.
Approved standards:
UL60950-1, cUR CSA C22.2 No. 60950-1, EN 50178,
and EN 60950-1.
Lineup includes open-frame models, models with.
chassis, and models with chassis and covers.
Wide-range power supply: 100 to 240 VAC.
Complies with harmonic current standard in EN.
61000-3-2 (50-W to 240-W models) K2CM-Q4L OMRON.
The top class in industry for compact size.
Boost current output (some models excluded). Time specification: Inverse type.
Current setting range: 20 to 65 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage K2CM-Q4L OMRON.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Cable type: Standard Cables.
Type: Cable with Plugs on Both Ends (M12 Right-angle/M12 Right-angle) .
Cable length: 15 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks. Type: S8JC-Z series models list.
Meet the criteria: No.
Configuration: power supply wwith cover; DIN guide rail mounting K2CM-Q4L.
Input voltage: 150W.
Output voltage: 5VDC.
Output current: 30.0A.
Economic type power supply S8JC-Z additional models,
The new power S8JC-ZS has a CE certification mark to market.
Product features: reducce material costs;
Export machinery to be used to meet specific safety standards;
Through the DIN guide rail installation, significant savings in time K2CM-Q4L.