Input terminals: M3 terminals.
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
SSR Short-circuit Failure Detection, Common).
Applicable load (See note.): 2 to 25 A, 100 to 240 VAC.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heaters.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
screw terminals (detachable).
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified.
Type: 4 poles.
Classification: Bifurcated contacts, Standard models.
Rated voltage: 100/110, 110/120, or 200/220 VAC; 12 or 24 VDC .
New Latching Levers for Circuit Checking.
Added to Our Best-selling.
MY General-purpose Relays.
Now lead-free to protect the environment.
VDE certification (Germany) G3PF-225B OMRON.
Different colors of coil tape for AC and,
DC models to more easily distinguish them
G3PF-225B
MY(S) models with latching levers added for,
easier circuit checking. Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: Yes(Yellow).
Applicable output load (See note 1.): 75 A at 24 to 240 VAC(See note 2.).
Rated input voltage: 100 to 120 VAC.
Wide Lineup of General-purpose Solid State G3PF-225B OMRON.
Relays with Applicable Loads of 5 to 90 A.
AC Output Relays with 75-A and 90-A output currents have been,
added to the G3NA Series.
All models feature the same compact dimensions to provide a,
uniform mounting pitch.
Built-in varistor effectively absorbs external surges.
(except G3NA-D210B).
Operation indicator enables monitoring operation.
Protective cover for greater safety.
Standard models certified by UL and CSA and -UTU models by TÜV G3PF-225B OMRON.
(except G3NA-410B, G3NA-420B, and G3NA-440B(-2)). Isolation method: Relay.
Zero cross function: No.
Operation indicator: Yes.
Applicable output load(See note.): 10 A 100 to 240 VAC.
Rated input voltage: 12 VDC.
Hybridization of a Magnetic Relay and an,
SSR Achieves 10-A Switching for 10 Million,
Operations.
UL/CSA certified (-VD models).
Using a triac to open and close the circuit reduces chattering,
and arching, thereby increasing the electrical durability to 10,
million operations.
Relays contacts for power ON and 10-A switching with high,
capacity are provided in a compact body without the need of,
radiators G3PF-225B. Plus, there is almost no effect on heat generation,
or ambient temperature.
Operation indicators to easily check operation.
Built-in teemperature fuse prevents internal burning due to,
triac or relay malfunctions G3PF-225B.
Socket-type Relays the same size as the 1-pole and 2-pole,
LY Relays.