LK Automation Limited LK Automation Limited
Brand: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Go Back >> Product Catalogues
G3FD-102SN-VD DC5-24 OMRON Solid State Relays
Brand: OMRON
Name: Solid State Relays
Model: G3FD-102SN-VD DC5-24
Isolation: Photocoupler.
Zero cross function: --.
Indicator: Yes.
Rated output load: 2 A at 5 to 110 VDC.
Rated input voltage: 5 to 24 VDC.
International Standards for G3F Series,
Same Profile as MY Power Relays.
Shape-compatible with mechanical relays.
Certified by UL, CSA, and VDE (model numbers with a suffix of“-VD”).
Socket type, same size as MY Power Relays.
Operation indicator provided to confirm input.
(model numbers with “N” before the suffix).

Action mode alarm contact: no lock, B contact.
Category: auxiliary contact.
Relay number: 2.
Relay circuit unit suitable for centralized alarm device of various control circuits.
MYA combination of multiple MY4 micro power relay, with all kinds of alarm function.
Small, socket type, so it can effectively use the space, repair, maintenance and other operation is simple and convenient G3FD-102SN-VD DC5-24 OMRON G3FD-102SN-VD DC5-24
By use, roughly divided into 4 types, to adapt to the full range of models.
Lloyd standard certified products (MYA-LA12, -LB12). Mounting type: PCB mounting.
Contact form: DPST-NO/DPST-NC.
PCB terminals.
A High-capacity, High-dielectric-strength,
Multi-pole Relay Used Like a Contactor.
Miniature hinge for maximum switching power for motor loads,
as well as resistive and inductive loads G3FD-102SN-VD DC5-24 OMRON.
No contact chattering for momentary voltage drops up to 50%,
of rated voltage.
Withstanding more than 4 kV between contacts that are differ,
ent in polarity and between the coil and contacts.
Flame-resistant materials (UL94V-0-qualifying) used for all in,
sulation material.
Standard models approved by UL and CSA G3FD-102SN-VD DC5-24 OMRON. Input terminals: Compact slotted screw terminals (detachable).
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection).
Applicable load (See note.): 2 to 35 A, 100 to 240 VAC.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phasee heaters G3FD-102SN-VD DC5-24.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp termiinals (detachable), or compact slotted,
screw terminals (detachable) G3FD-102SN-VD DC5-24.
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified.


...More relevant models >>>>