FX2N-48MT-ES/UL | MITSUBISHI FX2N-48MT-ES/UL PLC
Brand: MITSUBISHI
Name: PLC
Model: FX2N-48MT-ES/UL
Max input / output points: 48 points.
Supply voltage: 100 - 240VAC.
Input points: 24 points.
Output points: 24 points.
Output type: transistor.
Power consumption: 50VA.
Weight (kg):0.85.
Size (WxHxD) mm:182x90x87.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eight digit password to protect your program.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).

Apply PLC:FX2N (up to 3 units), FX3U (up to 3 units).
Applicable PLC:FX2NC (to FX2NC-CNV-IF, up to 1 units), FX3UC (to FX2NC-CNV-IF or FX3UC-1PS-5V, up to 3 units).
The rotation angle detecting unit is controlled by the mechanical cam switch,
The rotation angle is detected by using the special detector, and the rotation position control with high precision is realized MITSUBISHI FX2N-48MT-ES/UL.
Using the setting unit, it is easy to realize the setting and monitoring of the action resolution FX2N-48MT-ES/UL
The detection of rotation angle can be accurate to the high accuracy of 415rpm/0.5 degree or 830rpm/1.0 degree unit.
Built without battery to maintain the EEPROM, the maximum can store 8 kinds of procedures.
The cable that is assembled in the device without the brush can be extended to 100m MITSUBISHI FX2N-48MT-ES/UL.
When used alone, the CC-LINK type FX2N-32CCL interface module can be used to connect to the CC-LINK system.
Product composition:
FX2N-1RM: the main body of programmable cam switch (with setting panel).
F2-720RSV: no brush splitter.
FX2N-RS-5CAB: splitter cable (5m).
PLC connecting cable (55mm). Special module for RS-232C communication MITSUBISHI FX2N-48MT-ES/UL.
This serial communication module, you can communicate with the computer, printer, code reader and other equipment with RS-232C communication function.
The data can be transmitted through the buffer storage area of the module, and the data transfer between the PLC host and the module is realized FX2N-48MT-ES/UL MITSUBISHI.
When you connect to FX3UC, you need FX2NC-CNV-IF or FX3UC-1PS-5V. PC-9800 computer (half pitch 14 pin)20 pin connector on both ends of the circular multi-core cable FX2N-48MT-ES/UL MITSUBISHI.
Length 1.5M. Max input / output points: 14 points.
Power supply voltage: DC24V.
Input points: 8 points.
Output points: 6 points.
Output type: Transistor (source).
Power consumption (W): 19.
Weight (kg):0 FX2N-48MT-ES/UL MITSUBISHI. 3.
Size (WxHxD) mm:60x90x75.
Positioning and pulse output functions: a PLC cell can output 2 point 100KHz pulses at the same time.
PLC is equipped with 7 special positioning instructions,
Including zero return, absolute or relative address expression and special pulse output control.
Host has 10 points (6I/4O), 14 points (8I/6O), 20 points (12I/8O), 30 points (16I/14O) of 4 types.
This type of PLC is mainly used in all of the digital input, digital output control point of the device.
Can be directly connected to the 220V city power, built-in 8K step EEPROM memory, no battery, easy to maintain FX2N-48MT-ES/UL.
The series transistor output (MT) of the PLC, can be output 2 100KHz pulse, direct drive servo or stepper motor.
The series PLC can not be brought with the expansion module, but can be installed by the BBD board to extend a small amount of I/O MITSUBISHI FX2N-48MT-ES/UL.
The series 1N through the installation of BD series PLC board, can achieve RS232, RS485, RS422 communication.