LK Automation Limited LK Automation Limited
Brand: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Go Back >> Product Catalogues
FA-TH16YTL11S | MITSUBISHI FA-TH16YTL11S Terminal module
Brand: MITSUBISHI
Name: Terminal module
Model: FA-TH16YTL11S
Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.

Input points: 32 points.
Input voltage: DC24V.
Enter the public side of the way: 32 points / public.
Output form: transistor output (source).
Output points: 32 points.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have
Output common way: 32 point / common.
Input / output occupied points: 32 points (I/O distribution: input and output mixed 32 points) MITSUBISHI FA-TH16YTL11S FA-TH16YTL11S
External wiring connection: 40 pin connector two.
1, the switch quantity acquisition and switch control and RS-485 bus are isolated from each other, and isolated from the whole system.
2, the power supply line has anti reverse connect function, once the wrong power line,
Will automatically cut off the power to protect the entire module is not damaged MITSUBISHI FA-TH16YTL11S.
With over-voltage protection function, when the voltage is too high, automatic disconnection,
Protecting the entire module is not damaged.
3, RS-485 interface with 600W lightning protection and surge protection function, with 3000V photoelectric isolation.
4, the use of Modbus protocol, good general, can be very convenient and other systems,
Customers can also according to their own personal needs, custom related agreements, convenient and flexible MITSUBISHI FA-TH16YTL11S.
5, communication lines using RS-485 bus, support for multiple modules in parallel use,
Easy to expand the system, good scalability FA-TH16YTL11S MITSUBISHI. The built-in I/O function (Location: 1 axis) of the pulse output is converted to a differential drive output.DC input.
Number of input channels: 2Ch FA-TH16YTL11S MITSUBISHI.
DC5/12/24V input.
Maximum count rate: pulse/s 200k.
Linear counter function.
Ring counter function.
Uniform output function.
Preset function.
Count invalid function.
Latch counter function.
Sampling counter function.
Periodic pulse counter function.
Flexibly applied to various applications
Combination of functions,
Easy to achieve speed measurement, long measuring function, the single pulse output, the ratio of the set / distribution output, PWM control, cam switch control, such as a wide range of control FA-TH16YTL11S MITSUBISHI.
Single pulse.
To trigger the input as a starting point, with a minimum 25ns unit to adjust the ON/OFF time.
The action time deviation of ON/OFF is ns level, so it can achieve high precision control.
Velocitty measurement and length measurement
In addition to the measurement of ON width and OFF width,
Can also achieve different sensor ON time difference and other conditions of the measurement FA-TH16YTL11S.
The high precision measurement of the smallest 25ns unit can be realized MITSUBISHI FA-TH16YTL11S.
Delayed output
The output time delay of each channel can be adjusted so that the error output can be realized.


...More relevant models >>>>