F3SG-4RA0670-30 OMRON Safety Light Curtain Advance type
Brand: OMRON
Name: Safety Light Curtain Advance type
Model: F3SG-4RA0670-30
Number of beams: 32.
Protective height: 670mm.
New Standard of Safety Light.
Curtain,Offering Both Robustness.
and Reliability.
Robust and compact.
New muting function to increase both productivity and safety.
All models designed for global use. PNP/NPN selection by.
DIP switch.
Conforming to major international standards including.
Chinese standard GB 4584.

Release Key Type: Standard (metal).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Solenoid lock Mechanical release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 6-contact Model,
Insert the built-in switch (N, P, Q or R) into the blank @ F3SG-4RA0670-30 OMRON.
Conduit size (See Note.): 1/2-14NPT F3SG-4RA0670-30
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available) F3SG-4RA0670-30 OMRON.
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames.
The plastic material makes the Slide Key suitable,
for lightweight doors F3SG-4RA0670-30 OMRON. Number of beams: 132.
Protective height: 1199mm.
Model: PNP output.
Basic Type with a combination of.
performance and functionality.
Up to three sets of series-connected sensors.
The muting function is enabled simply with Muting Key Cap.
Comes standard with interlock and auxiliary output functions. Name: Safety Network Controllers.
No. of I/O points: Safety inputs, 40; Test outputs, 8; Safety outputs, 8.
Unit version: 2.0.
Achieve Safety Control through,
Programming.
Compact Safety Conttroller F3SG-4RA0670-30.
The NE1A-SCPU01-V1 provides 16 built-in safety inputs,
and 8 built-in safety outputs.
The NE1A-SCPU02 provides 40 built-in safety inputs and,
8 built-in safety outputs.
Reduced wiring with safety networks. Connect up too 32,
Safety Terminals F3SG-4RA0670-30.
Monitor the safety system from Standard Controllers,
across the network.
ISO13849-1 (PLe) and IEC 61508 SIL3 certification.