DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
The use of communication adapter cable (sold separately) connected to the computer, without power supply connection
With auxiliary output (maximum 2 points), event input (maximum 1 points), the basic function is complete.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm).
Size: 96 × 96 mm.
Control type: 2-loop control.
Control mode: 2-loop standard control, 2-loop heating and cooling control,
Single-loop cascade control, Single-loop control with remote SP,
Single-loop proportional control.
Outputs(control/transfer): 4 points: Pulse voltage (2 points) and
Pulse voltage/current (2 points) OMRON E5DC-CX2AUM-015.
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, None; Serial communications, Yes
E5DC-CX2AUM-015
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity.
A short sampling period of 50 ms enables use in applications,
requiring high-speed response.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight OMRON E5DC-CX2AUM-015.
Multiloop control, cascade control, and proportional control are,
possible with a single Controller.
When using models with CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4.0 or higher).
Equipped with calculation functions as a standard (e.g., square,
root calculation and broken-line approximation) OMRON E5DC-CX2AUM-015.
DeviceNet Communications.
Data setting and monitoring can be performed without special programming. Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 3 E5DC-CX2AUM-015 OMRON. 2 dia.
Protective tubing length L: 20 cm.
Lead wire type: Standard.
Lead wire length M: 4m.
A Wide Variety of High-precision.
Temperature Sensors E5DC-CX2AUM-015 OMRON.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5DC-CX2AUM-015 OMRON. Control output 1: Relay output.
Control output 2: Relay output.
Auxiliary output: Two.
Communications: --.
Heater burnout: One.
Event inputs: Four.
Power supply voltage: 100 to 240 VAC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to Setup and Operration E5DC-CX2AUM-015.
A Complete Range of I/O Capacities,
Functions, and Performance.
Handles More Applications.
The white PV display with a height of 15.2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm OMRON E5DC-CX2AUM-015.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature,