LK Automation Limited LK Automation Limited
Brand: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Go Back >> Product Catalogues
E5CN-CL | OMRON Foundation type temperature controller E5CN-CL
Brand: OMRON
Name: Foundation type temperature controller
Model: E5CN-CL
Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard.
Auxiliary output points: -.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.

Terminal type: Exposed-lead Models.
Protective tubing diameter D: 3.2 dia.
Protective tubing length L: 20cm.
Lead wire type: Heat resistive.
Lead wire length M: 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work OMRON E5CN-CL.
Ideal for the thermal input devices of Temperature Controllers E5CN-CL
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. The main body: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V) OMRON E5CN-CL.
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade OMRON E5CN-CL.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type E5CN-CL OMRON.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay E5CN-CL OMRON. Classification: Low-cost Models.
Description: Low-cost platinum resistance thermometer.
Temperature range (See note 3.): -50°C to 250°C.
Element type: Pt100.
Conductor type: 3-conductor system E5CN-CL OMRON.
Class: B.
Protective tubing material: SUS304.
Terminal type: Exposed lead wires.
Page: 37.
A Wide Variety of High-precision.
Temmperature Sensors E5CN-CL.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal OMRON E5CN-CL.


...More relevant models >>>>