Specifications: Outputs, PNP (+ common), 4 points.
I/O connections: Sensor I/O connector.
Supplied from the communications. connector.
Rated I/O power supply voltage: 24 VDC.
Remote I/O Terminals with High.
Degree of Environmental Resistance.
(IP67) in Product Lineup Including.
Economical Input, Output, and Mixed I/O Models.
operation status monitoring and effective maintenance.
construction. (IP67)
connection with hydraulic valve devices.
Specifications: Inputs; NPN (+ common);
16 points.
I/O connections: M3 screw terminals.
Rated internal circuit power supply voltage:
Supplied from Basic Unit.
I/O power supply voltage: 24 VDC.
A Smart Slave with a 3-tier Terminal,
Block That Means Wiring Locations,
Are Easy to Understand with No,
Sharing of Terminals OMRON DRT2-OD04CL-1.
Easy wiring with no sharing of terminals.
Easy-to-understand wiring locations
DRT2-OD04CL-1
No relay terminal block terminals required.
Detachable cassette-type circuit sections. Name: CompoNet Communication Unit.
Specifications: Up to 64 Slice I/O,
Units can be connected.
(Inputs: 32 bytes maximum,
Output: 32 bytes maximum).
Standards: CE, UC1, L.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet OMRON DRT2-OD04CL-1.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error OMRON DRT2-OD04CL-1. Name: Three-tier Screw Terminal Block.
Specifications: Inputs/Outputs;
8 inputs/8 outputs; PNP;
With Short-circuit and,
Disconnected Line Detection DRT2-OD04CL-1 OMRON.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced DRT2-OD04CL-1 OMRON.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error DRT2-OD04CL-1 OMRON. Unit type: 10 I/O points 6 inputs; 4 outputs, Connector.
Input: 6 points: 24 VDC.
Output: 4 points: transistor (sinking).
Clock: Yes.
Slaves with the Complex Functionality Needed,
for Distributed Blocks.
Programmable Slaves combine devices, such as sensors and actuators,
into one functional unit that is treated as a DeviceNNet slave DRT2-OD04CL-1.
Programmable Slaves greatly facilitate device distribution,
and functional organization.
They help standardize programming between units and reduce the amount of,
programming required at the master.
I/O and operattional checks can be performed for each functional unit,
rather than waiting OMRON DRT2-OD04CL-1.
for final system assembly, as with conventional distributed I/O systems.