LK Automation Limited LK Automation Limited
Brand: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Go Back >> Product Catalogues
DRT2-ID16SLH-1 | OMRON DRT2-ID16SLH-1 Screw-less Clamp Terminals with Transistors
Brand: OMRON
Name: Screw-less Clamp Terminals with Transistors
Model: DRT2-ID16SLH-1
Short/disconnection detection: Supported.
Specifications: Inputs, PNP (- common), 16 points.
I/O connections: Clamp terminals.
Rated internal circuit power supply voltage:
Supplied from communications connector.
Rated I/O power supply voltage: 24 VDC.
Reduced Wiring and Labor on Factory Sites with Screw-less Terminal Wiring.
Screw-less structure eliminates tightening work.
Detachable terminal blocks for easier maintenance.
Single-step wiring by simply inserting pole terminals.

I/O classification: Digital output.
Internal I/O circuit common: PNP (+ common).
I/O points: 8.
I/O connection method: Sensor connector.
Compact Remote I/O Terminals that.
Save Wiring Effort and Enable.
Long-distance Communications.
Long-distance or high-speed communications,
mode is selectable OMRON DRT2-ID16SLH-1.
Incorporates I/O connectors making it possible to,
minimize the size.
I/O connectors save wiring effort DRT2-ID16SLH-1
Flexible DIN track mounting is possible through a,
DIN track attachment.
Eight-point sensor connector models and 16-point,
MIL connector models are the same size. I/O classification: Input.
Internal I/O circuit common: PNP (– common).
I/O points: 8.
Rated voltage: 24 VDC.
I/O rated voltage: 24 VDC OMRON DRT2-ID16SLH-1.
Long-distance Communications Supported by SRT2 Models,
(Long-distance/High-speed Communications Selection).
Ultra-compact at 80 x 48 x 50 (W x H x D) mm for,
4-point and 8-point terminals and 105 x 48 x 50,
(W x H x D) mm for 16-point terminals.
Two independent power supplies can be used,
because the I/O terminals are insulated from the internal circuits.
DIN track mounting and screw mounting are both supported OMRON DRT2-ID16SLH-1. Input/Output: Outputs.
Internal I/O circuit common: PNP (+ common).
I/O points: 4 points.
I/O connection method: Sensor connector.
Rated voltage for I/O power supply: 24 VDC DRT2-ID16SLH-1 OMRON.
Eight Waterproof Terminal Models.
Emphasizing Cost Efficiency.
Reduced Labor.
Connection using connectors reduces the lead time,
required for installation DRT2-ID16SLH-1 OMRON. No tools are required for,
connection to a variety of devices.
Reduced Wiring.
Signal line wiring has been reduced so that the,
Terminal can be mounted closer to sensors and,
other devices.
Relay Box not Required.
Environment-resistant, dust-tight, drip-proof,
construction (IP67) enablles direct on-site,
mounting DRT2-ID16SLH-1 OMRON DRT2-ID16SLH-1.
Easier Maintenance.
Significant reductions not only in setup time but also,
maintenance time.
Reduced Space, Improved Operability,
Compact design (160 x 54 mm (W x H)) (88-point models) OMRON DRT2-ID16SLH-1.
Settings and connections can be performed using,
the switch and connectors on the front side of the Terminal.
System Configuration.


...More relevant models >>>>