Name: I/O Control Unit.
CS-series Connecting Cable.
26V system, --.
Standards: UC1, CE.
and Expansion I/O Cables.
Unit type: CS1 Special I/O Units.
name: Position control unit.
Specifications: Control method/Control,
output interface, Open-loop control by,
pulse train output/Open-collector output;
Number of control axes, 1 axis.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.25A; 26V, --.
Standards: U, C, N, L, CE CS1D-IC102D OMRON.
High-speed, High-precision,
positioning with 1, 2, or 4 axes
CS1D-IC102D
Versatile functions and superb,
performance enable the construction,
of compact, high-performance machines.
With its ultra-compact size of 31×90mm,
(W×H),this highly space-efficient Position,
Control Unit(PCU) enables up to 4 axes,
of motor control.I/O bits: 5, 120 (Expan-sion Racks: 7).
Program capacity: 250K steps CS1D-IC102D OMRON.
Data memory capacity: 448K words (DM: 32K words, EM: 32K words ×13 banks).Unit type: CS1 Basic I/O Units.
Product name: B7A Interface Unit.
Specifications: 32 inputs/outputs.
Mountable Racks: CPU Rack, CS1W-BC,
@@3, Yes, @@2, Yes;
C200HX/HG/HE Expansion I/O Rack, No.
CS1 Expansion Rack, CS1W-BI,
@@3, Yes, @@2, Yes;
CS1 Long distance Expansion Rack, Yes;
SYSMAC BUS Slave Rack, No CS1D-IC102D OMRON.
Words required: 2 input words and 2 output words.
Current consumption: 5V system, 0.09A;
26 V system, --.
Standards: UC1, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. Unit type: CS1 Special I/O Units.
Product name: Isolated-type DC Input Unit.
Input points : 4 inputs.
Signal range: 4 to 20 mA, 0 to 20 mA,
1 to 5 V, 0 to 5 V, ±5 V, 0 to 10 V, ±10 V.
Conversion speed (resolution):
100ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.16A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems CS1D-IC102D.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CS1D-IC102D.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.