CRT1-ID08SL OMRON CRT1-ID08SL
Brand: OMRON
Name: CompoNet Gateway Unit for CC-Link
Model: CRT1-ID08SL
Name: Clamp Terminal Blocks.
Specifications: Inputs; 8 inputs ; NPN; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.

Internal I/O common: PNP.
I/O indicators: LED display (yellow). 140 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 220 g max.
Expansion functions: No.
Short-circuit protection function: Available at input,
section only (Operates at 50 mA/point min OMRON CRT1-ID08SL. )
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary CRT1-ID08SL
Digital I/O terminal with industry,
standard e-CON connectors.
A common terminal is provided for,
each connector.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
switch and with tool software OMRON CRT1-ID08SL.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance. Unit: Connector model.
I/O classification: Digital output.
Internal I/O common: NPN (- common).
I/O points: 16.
I/O connections: Molex connector.
Power supplyvoltage: 24 VDC.
I/O specification: 0.5 A, DC/transistor.
Digital I/O Units Compatible with MULTIPLE I/O TERMINAL,
Terminal block, connector, and high-density connector,
models are available OMRON CRT1-ID08SL.
The circuit block of the terminal block model can be,
mounted or dismounted for ease of maintenance without,
disconnecting the wires.
DIN track mounting. I/O classification: Temperature inputs.
I/O points: 4 inputs.
I/O connections: Terminal block.
Power supply voltage: 24 VDC.
Input specification: Platinum resistance thermometer.
Temperature Input Units for use with MULTIPLE I/O TERMINAL.
Four inputs.
Thermocouples and platinum resistance thermometer models,
are available.
Conversion time is only 250 ms for 4 inputs.
The Configurator can be used to calibrate temperatures.
The circuit section can be removed, so rewiring isn’t,
required during maintenance.
DIN track mounting. Specifications: I/O; PNP (input: - common, output: ++ common);
16 inputs/16 outputs CRT1-ID08SL.
I/O connections: MIL connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Very Compact 16-/32-point Remote Termminals CRT1-ID08SL.
Used in combination with Interface,
Conversion Boards (e.g., D-Sub) to,
connect to a wide range of interfaces.
35 x 60 x 80 mm (W x D x H).