CPU R08SFCPU MITSUBISHI R08SFCPU
Brand: MITSUBISHI
Name: CPU
Model: R08SFCPU

Safety grade (SIL): SIL 3 (IEC 61508).
Performance level (PL): e PL (13849-1 EN/ISO).
Operation control mode: stored procedures repeated operation.
Program capacity: 80K (security program: 40K).
Program memory: 320K.
Soft element / tag memory: 1178K.
Data memory: 5M.
In line with the international safety standards for the safety of CPU can be controlled at the same time the general system and safety system MITSUBISHI R08SFCPU R08SFCPU
Available through IE Field CC-Link network,
Connect the safety switch and safety light curtain system used to secure CPU,
System for the construction of a general control and safety control system.
In addition, through the use of intuitive engineering software Works3 GX,
Focus on general control and safety control programming MITSUBISHI R08SFCPU.
Integrate security functions into the control system.
Can be used in the previous iQ-R MELSEC series module as a general control purposes,
Use on the same substrate, it can be used to construct a hybrid system with general control and safety control.
Moreover, IE Field CC-Link network can be integrated with general communication and secure communication,
Ethernet cable can also be used in secure communication,
No need to use a dedicated cable, etc MITSUBISHI R08SFCPU. . Analog input channel number: 16CH.
accuracy
Ambient temperature of 25 plus or minus 5 degrees C: plus or minus 0.1%.
Ambient temperature 0 ~ 55 degrees C:- R08SFCPU MITSUBISHI.
Temperature coefficient: positive and negative 35ppm/.
Common
Conversion speed: 10ms.
Insulation between channels: isolation transformer insulation R08SFCPU MITSUBISHI.
Absolute maximum input: positive and negative 15V, 30mA.
External wiring connection: 40 pin connector two.
Voltage input
The analog input voltage: DC - 10 - 10V.
Digital output value: 32000 ~ 32000.
Current input
Analog input current: DC0 ~ 20mA.
Digital output value: 0 ~ 32000 R08SFCPU MITSUBISHI.
Execute event driven program through alarm output
Strengthen the implementation of the interrupt function according to the alarm output flag, easy to carry out preventive maintenance.
The measured value and the change rate of the analog input signal exceed the upper and lower limits of the set,
Regardless of the procedure of the scan time, can be executed interrupt handling, quickly respond to abnormal conditions.
Analog input module for the external analog signal into the interface of the programmable controller.
Can choose the channel between the insulation, voltage input, current input, voltage / current mixed input, thermocouple input, temperature resistance (RTD) input for a variety of purposes, such as modules R08SFCPU.
Filter high frequency interference.
Analog input module has been equipped with a first order lag filter.
The analog input signal with high frequency interferencee component can be obtained by using the first order lag filter MITSUBISHI R08SFCPU.
Parameters can be set through the filter time constant, no program can be easy to use.