LK Automation Limited LK Automation Limited
Brand: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Go Back >> Product Catalogues
CL1PSU-2A | MITSUBISHI Dedicated power supply CL1PSU-2A
Brand: MITSUBISHI
Name: Dedicated power supply
Model: CL1PSU-2A
Input voltage rating: AC100/120/230/240V
External connection mode: module power supply: Terminal 3 pin (M3 screw), communication line / module power supply unit.
Dedicated power supply for CC-LINK/LT system with built-in 2A power supply.

Input type: DC input, positive common end.
Input points: 8 points.
Enter the response time: 0.2ms the following.
Rated input voltage / current: DC24V/5mA.
Output form: transistor output, leakage type.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC24V/0 MITSUBISHI CL1PSU-2A. 5A.
External connection: 1 line /1 line type.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup CL1PSU-2A
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool MITSUBISHI CL1PSU-2A. A pack of 20.
Applicable models:
AJ65SBTC - - - type remote I/O module.
AJ65VBTCU - - - type remote I/O module.
AJ65VBTCU- - type remote I/O module. A pack of 5.
Applicable models:
AJ65VBTS - - - type.
AJ65VBTCE - - - type.
AJ65VBTCU - - - type.
AJ65ABTP - - - type.
AJ65VBCU- - type. Enter 8 points: 24VDC.
4 wire type.
Response time: 1.5ms.
Output 8 points: 24VDC.
Transistor output MITSUBISHI CL1PSU-2A.
Waterproof connector type.
MITSUBISHI PLC hardware implementation
Hardware implementation is mainly for the control cabinet and other hardware design and field construction.
Design control cabinet and the operating table and other parts of the electrical wiring diagram and wiring diagram CL1PSU-2A MITSUBISHI.
Electrical interconnection diagram of each part of the design system.
According to the construction drawings of the site wiring, and carry out a detailed inspection CL1PSU-2A MITSUBISHI.
Because the program design and hardware implementation can be carried out at the same time,
So the design cycle of the MITSUBISHI PLC control system can be greatly reduced.
MITSUBISHI PLC online debugging.
On-line debugging is the process that will through the simulation debugging to further carry on the on-line unification to adjusst CL1PSU-2A MITSUBISHI CL1PSU-2A.
On-line debugging process should be step by step,
From MITSUBISHI PLC only connected to the input device, and then connect the output device, and then connect to the actual load and so on and so on stepp by step MITSUBISHI CL1PSU-2A.
If you do not meet the requirements, the hardware and procedures for adjustment.
Usually only need to modify the part of the program can be.


...More relevant models >>>>