LK Automation Limited LK Automation Limited
Brand: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Go Back >> Product Catalogues
AJ65VBTCE3-16DTE | MITSUBISHI AJ65VBTCE3-16DTE Sensor connector type DC input / transistor output module
Brand: MITSUBISHI
Name: Sensor connector type DC input / transistor output module
Model: AJ65VBTCE3-16DTE
Input type: DC input, negative public end.
Input points: 8 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA.
Output form: transistor output, source.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC24V/DC24V/0.1A.
External connection: 3 line /2 line type.
Sensor connector type (E-CON type).
Using industry standard E-CON type.
Simple wiring through sensor connector.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input.

Output type: transistor output, drain type.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC12V/DC24V/0.1A.
External connection: 2 wire.
Screw terminal table type.
Minimum size of industry.
The connection object at a glance with terminal cover plate MITSUBISHI AJ65VBTCE3-16DTE.
Input module for public end of positive pole and negative pole AJ65VBTCE3-16DTE
Terminal table structure capable of connecting with 2 wire type sensor and load in the same condition.
Can be installed along the 6 direction. Description: supporting the use of AJ65BT-RPI-10A and AJ65BT-RPT-10B, support 156K/625K/2.5Mbps.
Station type: take up 1 stations for the remote I/O.
Spare 5 products for different purposes MITSUBISHI AJ65VBTCE3-16DTE.
Thin waterproof type relay hub.
Extension of star type wiring and main line length, waterproof structure.
Spring clip terminal type relay hub.
Star type wiring, length of the main line, spring clamping terminal table type.
Relay appliance (T branch) unit.
Extension of T type branch and trunk length.
Relay unit in light.
In the presence of interference in the environment of the wiring, the length of the trunk line MITSUBISHI AJ65VBTCE3-16DTE.
Relay unit in space light.
Communication between linear moving bodies. Pulse input: DC input.
Default input: DC input.
Count range: 0~16777215.
Number of stations: 4 stops.
Station type: remote equipment station AJ65VBTCE3-16DTE MITSUBISHI.
Configuration of master / local station,
In addition to the other site network with different CC-Link in addition to the main station and the remote station configuration can also be the main station and the local station configuration AJ65VBTCE3-16DTE MITSUBISHI.
A local PLC can communicate with the master station PLC and other remote workstations. Output type: transistor output, drain type.
Output points: 16 points.
OFF leakage current: 0.1mA AJ65VBTCE3-16DTE MITSUBISHI.
Output protection function.
Rated load voltage / current: DC24V/DC24V/0.1A.
External connection: 2 wire.
Fast connector type.
Simple wiring through quick connector.
Can be installed along the 6 direction.
MITSUBISHI PLC program simulation debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of thee program MITSUBISHI AJ65VBTCE3-16DTE AJ65VBTCE3-16DTE.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation.


...More relevant models >>>>