A1S62TCRTBW-S2 | MITSUBISHI A1S62TCRTBW-S2 Temperature control module
Brand: MITSUBISHI
Name: Temperature control module
Model: A1S62TCRTBW-S2
Number of channels: 2 channels.
Sensing method and temperature range: PT100.
A1S64TC series component is a kind of temperature controller combined with ANS series CPU.
Components with temperature measurement input and built-in PID algorithm control output, can be used in a variety of temperature control occasions.
Each component controls up to 4 loops at most.
Thermocouple input or PT100 3 wire temperature sensor input.
Control output switching signal for the output of the transistor.
BW is a signal with broken line detection function.

Cable length: 3 meters
Extending cable to connect CPU main substrate and extended substrate,
According to the model can provide different cable length,
If you need to connect the AnN type expansion substrate is required,
Selection of A1SC05NB (A1SC07NB) cable. Input points: 32 points.
Input voltage and current: 7mA DC24V MITSUBISHI A1S62TCRTBW-S2.
Input response time: 10ms.
16 point /1 a public side A1S62TCRTBW-S2
Positive pole sharing.
Output points: 24 points.
Output voltage: DC24V/AC240V, 2A/1 point, 5A/1 common end.
Output response time: 12ms.
Output type: relay output.
8 point /1 a public side.
34 point terminal station.
PLC is introduced by the relay control technology after the development of micro processing technology,
Can be easily and reliably used for switching control MITSUBISHI A1S62TCRTBW-S2.
As the analog quantity can be converted into digital quantity, the number of digital quantity is just a number of switching value,
Therefore, after the conversion of analog, PLC can also be reliable for processing control.
Because the continuous production process often has the analog quantity, the analog quantity control is sometimes called process control MITSUBISHI A1S62TCRTBW-S2.
Analog quantity is not electricity, and PLC can only handle digital quantity, quantity of electricity.
All to realize the conversion between them to have the sensor, the analog quantity into a number of power A1S62TCRTBW-S2 MITSUBISHI.
If this power is not standard, but also through the transmitter,
The non-standard power into a standard electrical signal, such as 1-5V, 4-20mA, 0-10V, etc A1S62TCRTBW-S2 MITSUBISHI. .
At the same time, there is also an analog input unit (A/D),
Transform these standard electrical signals into digital signals,
The analog output unit (D/A), in order to transform the digital quantity after PLC processing into analog quantity -- standard electric signal.

So the standard telecommunication number, the conversion between the number of operations to use a variety of computing A1S62TCRTBW-S2 MITSUBISHI A1S62TCRTBW-S2.
This requires the resolution of the analog unit and the standard electricaal signal MITSUBISHI A1S62TCRTBW-S2. Liquid crystal display: 16 characters x 2 lines,