3G3RV-A4075-ZV1 | OMRON High functional type general purpose inverter 3G3RV-A4075-ZV1
Brand: OMRON
Name: High functional type general purpose inverter
Model: 3G3RV-A4075-ZV1
Specification: three phase 400V.
Power: 7.5KW.
Maximum output voltage: three phase AC380 ~ 480V (input voltage correspondence).
Rated voltage: three phase 480V ~ 50/60Hz AC380.
Weight: about 6kg.
In the inverter is equipped with the servo can play the same static torque with PG vector control function,
DeviceNet communication makes the application field more extensive.
The high functional specifications are concentrated in the compact.
Equipped with PG vector control.
Subsequent models of 3G3RV.
CV/VT selection function.
Rich online automatic adjustment function (self learning function).
CX-Drive software.
DeviceNet correspondence correspondence.
Multi function input and output function.
Colorful function.
Brake transistor built-in.
Protection function.

Function name: 3 phase 400V.
Power: 2.2KW.
Rated output voltage: 3 phase, 380 ~ 480V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched).
Weight: 1.9KG.
Dimension (w * h) 128mm *:108.
Outline dimension (deep):170.5mm.
Mechanical automation concept OMRON 3G3RV-A4075-ZV1.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication 3G3RV-A4075-ZV1
Driver programming function.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. Level: 3 phase 200V level.
Connecting resistance: 17 or more OMRON 3G3RV-A4075-ZV1.
Internal resistance value: 120W, 20W.
In 3G3MX2 with the use of the braking resistor, can shorten the motor deceleration time.
Alarm output terminal of regenerative braking unit.
The temperature relay built-in resistance or braking resistance optional activation,
A circuit to cut off the main power supply of the frequency converter. Function name: 3 phase 200V.
Power: 1.5KW.
Rated output voltage: 3 phase, 200 ~ 240V (the output voltage can not exceed the input voltage) OMRON 3G3RV-A4075-ZV1.
Built in brake unit (brake resistance needs to be matched).
Weight: 1.6KG.
Dimension (w * h) 128mm *:108.
Outline dimension (deep):170 3G3RV-A4075-ZV1 OMRON. 5mm.
Mechanical automation concept.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication 3G3RV-A4075-ZV1 OMRON.
Driver programming function.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. Box protection class: metal, IP00.
Terminal size: M8.
Line diameter: 30 square mm 3G3RV-A4075-ZV1 OMRON.

Weight: 4 3G3RV-A4075-ZV1. 6kg.
Used to reduce the noise from the power cord to the frequency converter or from the frequency converter to the power line.
Try to be close to the transducer for connection. Power supply: 3 phase 3 line rated volltage 500V AC OMRON 3G3RV-A4075-ZV1.
Rated current: 50A.
Weight: 3.7KG.
Used to reduce the noise generated by the inverter.
Try to be close to the transducer for connection.