LK Automation Limited LK Automation Limited
Brand: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Go Back >> Product Catalogues
3G3AX-RBU21 Regenerative braking unit OMRON 3G3AX-RBU21
Brand: OMRON
Name: Regenerative braking unit
Model: 3G3AX-RBU21
Level: 3 phase 200V level.
Connecting resistance: 17 or more.
Internal resistance value: 120W, 180W.
In 3G3MX2 with the use of the braking resistor, can shorten the motor deceleration time.
Alarm output terminal of regenerative braking unit.
The temperature relay built-in resistance or braking resistance optional activation,
A circuit to cut off the main power supply of the frequency converter.

Frequency converter input power: 3 phase AC400V.
Weight: 2.6KG.
Standard applicable line diameter: 3.5 square mm or more.
Used to suppress harmonic currents generated by a transducer.
The effect of harmonic current suppression is better than that of AC reactor,
And it can be used with AC reactor. Inverter input power: 3 phase / single phase AC200V OMRON 3G3AX-RBU21.
Weight: 2.1KG.
Standard applicable line diameter: 2 square mm or more 3G3AX-RBU21
Used to suppress harmonic currents generated by a transducer.
The effect of harmonic current suppression is better than that of AC reactor,
And it can be used with AC reactor. Specification: three phase 400V.
Power: 185KW.
Maximum output voltage: three phase AC380 ~ 480V (input voltage correspondence) OMRON 3G3AX-RBU21.
Rated voltage: three phase 480V ~ 50/60Hz AC380.
Weight: about 260kg.
In the inverter is equipped with the servo can play the same static torque with PG vector control function,
DeviceNet communication makes the application field more extensive.
The high functional specifications are concentrated in the compact.
Equipped with PG vector control.
Subsequent models of 3G3RV OMRON 3G3AX-RBU21.
CV/VT selection function.
Rich online automatic adjustment function (self learning function).
CX-Drive software.
DeviceNet correspondence correspondence.
Multi function input and output function.
Colorful function 3G3AX-RBU21 OMRON.
Brake transistor built-in.
Protection function. Function name: 3 phase 200V.
Power: 1.5KW.
Rated output voltage: 3 phase, 200 ~ 240V (the output voltage can not exceed the input voltage) 3G3AX-RBU21 OMRON.
Built in brake unit (brake resistance needs to be matched).
Weight: 1.6KG.
Dimension (w * h) 128mm *:108.
Outline dimension (deep):170.5mm.
Mechanical auutomation concept 3G3AX-RBU21.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication 3G3AX-RBU21 OMRON.
Driver programming function.
Current vector control.
High starting torque: 00 OMRON 3G3AX-RBU21. 5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H.


...More relevant models >>>>