Box protection class: metal, IP00.
Terminal size: M6.
Line diameter: 22 square mm.
Weight: 3.6kg.
Used to reduce the noise from the power cord to the frequency converter or from the frequency converter to the power line.
Try to be close to the transducer for connection.
Function name: three phase 400V.
Power: 0.4KW.
Maximum output voltage: three phase 380 ~ 480VAC (corresponding input voltage).
Rated voltage, frequency: three-phase power supply 380 ~ 50/60Hz, 480V.
Cooling way: natural wind cooling.
Weight: 1.1kg.
Simple but not simple, casual and not casual.
Homogenization of today, the quality of the subtle show OMRON 3G3AX-NFI27.
Standard configuration has RS485 interface, Modbus bus communication function
3G3AX-NFI27
3Hz provides more than 150% torque output.
2-15kHz carrier frequency, can achieve mute driver.
Equipped with simple energy saving function.
Compact size and uniform, and can be installed close to the side by side.
Signal output function for controlling external brake action OMRON 3G3AX-NFI27.
Software setting operation mode, no need to connect the control line can be used for speed control. Function name: 3 phase 200V.
Power: 2.2KW.
Maximum output voltage: three phase 200 ~ 240VAC (corresponding input voltage).
Rated voltage, frequency: three-phase power supply 200 ~ 50/60Hz, 240V.
Cooling: forced cooling.
Weight: 1.9kg.
Simple but not simple, casual and not casual.
Homogenization of today, the quality of the subtle show OMRON 3G3AX-NFI27.
Standard configuration has RS485 interface, Modbus bus communication function.
3Hz provides more than 150% torque output.
2-15kHz carrier frequency, can achieve mute driver 3G3AX-NFI27 OMRON.
Equipped with simple energy saving function.
Compact size and uniform, and can be installed close to the side by side.
Signal output function for controlling external brake action 3G3AX-NFI27 OMRON.
Software setting operation mode, no need to connect the control line can be used for speed control. Inverter input power: 3 phase / single phase AC200V.
Weight: 1.0KG.
Standard applicable line diameter: 1.25 square mm or more.
Used to suppress harmonic currents generated by a transducer 3G3AX-NFI27 OMRON.
The effect of harmonic current suppression is better than that of AC reactor,
And it can be used with AC reactor. Function name: single phase 200V.
Power: 0.4KW.
Maximum output voltage: three phase 200 ~ 240VAC (corresponding input voltage).
Rated voltage, frequency: single phase power supply 200 ~ 50/60Hz, 240V.
Cooling way: natural wind cooling.
Weight: 1.1kg.
Simple but not simple, casual and not casual.
Homogenization of today, the quality of the subtle show.
Standard configuration has RS485 interface, Modbus bus communication functtion 3G3AX-NFI27.
3Hz provides more than 150% torque output.
2-15kHz carrier frequency, can achieve mute driver.
Equipped with simple energy saving function.
Compact size and uniform, and can be installed close to the side by side.
Signal outpput function for controlling external brake action OMRON 3G3AX-NFI27.
Software setting operation mode, no need to connect the control line can be used for speed control.